Service points-Every 100 hours

CQ273570

ML70882,00009D3 -19-13JUN06-1/2


IMPORTANT: Recommended service intervals are for average conditions. Service more frequently if combine is used in extreme conditions.

1. Check connections on fuel injection lines. Retighten if necessary.

2. Replace drier filter if the system becomes contaminated with air or every 100 hours.

3. Check the tightness of hose clamps and connections. Retighten if necessary.

4. Check length of clean grain elevator slip clutch spring. Readjust, if necessary. See section "Service-Drives/Shields".

NOTE: Also check if the clutch reaches 50 engagements before the specified interval.

ML70882,00009D3 -19-13JUN06-2/2