Hydraulic Fluid Sample Collection

IMPORTANT: Take care not to contaminate the hydraulic fluid. Clean the area around the components before performing any service.

  1. Attach one end of the hose (A) to the pump body (B) and then tighten the nut (C).

    CQ294507
    CQ294507-UN-30APR13

    CQ294504
    CQ294504-UN-30APR13



  2. Install the bottle (D) by turning it clockwise.

    NOTE: The end of the hose (A) must have a minimum length "X" inside the bottle (D) so that it does not stay entirely in.

    IMPORTANT: Keep the bottle cap (D) inside the bag supplied with it, thus avoiding its contamination.

  3. Insert the hose (A) in the relief fitting (E) on the side of the fluid reservoir, so that the hose penetrates 50 mm (1.9 in.) the fluid level.

    IMPORTANT: Handle the hose (A) carefully avoiding its contact with any part of the harvester, and thus contaminating the fluid.

  4. Operate the pump manually for the fluid to be sucked. If the fluid is not sucked in, push the hose (A) a little more into the relief fitting (E).

    IMPORTANT: Never turn the pump (B) upside down, keep it in an upright position. Failure to observe this procedure may cause its contamination.

  5. When the bottle (A) is full, loosen the nut (B) for air to enter and the fluid stops from being sucked.

    CQ294508
    CQ294508-UN-30APR13

    CQ294509
    CQ294509-UN-30APR13



  6. Remove the hose from the relief fitting.

    NOTE: Be very careful when removing the hose so you do not spill any fluid on the ground.

  7. Remove the bottle (A) from the pump body by turning it counterclockwise.

    NOTE: After removing the bottle (A), store the pump properly, ensuring its no contamination.

  8. Cap the bottle (A).

  9. With the pump (A) in the vertical position, push the hose (B) down and wipe all traces of fluid.

    CQ294510
    CQ294510-UN-30APR13

    CQ294511
    CQ294511-UN-30APR13



  10. Turn the pump (A) 180°, and wipe all traces of fluid again.

  11. Pull out the hose (B) to outside the pump (A).

  12. Discard in a proper container the hose (A) and any other material that is contaminated with coolant during the collection procedure.

    CQ294513
    CQ294513-UN-30APR13

    CQ294512
    CQ294512-UN-30APR13



  13. Fill out the form (B) with the requested data and place it inside the bag (C).

  14. Place the bottle (D) into the bag (C) so that it is facing up (standing).

  15. Deliver the sample collected to your John Deere dealer's service department, and the dealer will send the sample to the laboratory for analysis.

OU90500,0000018-19-20130611