Calibration Procedures—When to Calibrate
This list shows all possible calibrations. Depending on machine
options listing shown may not match calibration menu shown on display.
IMPORTANT: Error codes shown on display if a problem exists
during a calibration procedure. Conditions causing error must be corrected
before continuing calibration.
-
“Basecutter Height”—Perform calibration when
base cutter height sensor components are replaced, serviced, or adjusted.
-
“Primary Extractor OL”—Perform calibration
when primary extractor fan components are replaced, serviced, or adjusted.
-
“Hydro Handle Position Cal”—Perform calibration
when hydro handle position sensor is replaced, serviced, or adjusted.
-
“Steering Wheel Position Cal”—Perform calibration
when steering wheel input device (SID) is replaced, serviced, or adjusted.
-
“Left Crop Divider Position”—Perform calibration
when left crop divider position sensor components are replaced, serviced,
or adjusted.
-
“Right Crop Divider Position”—Perform calibration
when right crop divider position sensor components are replaced, serviced,
or adjusted.
-
“Left Crop Divider Pressure”—Perform calibration
when left crop divider pressure sensor components are replaced, serviced,
or adjusted.
-
“Right Crop Divider Pressure”—Perform calibration
when right crop divider pressure sensor components are replaced, serviced,
or adjusted.
-
“Basecutter Target Height”—Perform calibration
when base cutter height sensor and crop divider position sensor components
are replaced, serviced, or adjusted.
-
“Hydro Displacement Field Cal”—Perform calibration
when pump EDC valve is replaced, serviced, or adjusted.
-
“Varitorque Cal”—Perform calibration when
varitorque potentiometer is replaced, serviced, or adjusted.
|
|
WM05597,0000D42-19-20131202
|
|