Operator Presence System
Operator presence system indicates the presence of the operator.
System prevents engagement of the following functions when operator
is not present in seat.
-
Separator Engage
-
Header Engage
-
Unloading Auger Engage
-
AutoTrac
-
Propulsion
-
Feedrate
-
Header Height Control
-
Kemper Roading Float Mode
If operator leaves seat with the header and/or separator engaged
for more than 5 seconds the header and unloading auger is disengaged,
before 11 seconds the separator is disengaged, lights flash and an
alarm sounds. If operator continues to be out of the seat, harvesting
functions stop.
To restart functions, operator must return to seated position
and re-engage each function.
|
AutoTrac is a trademark of Deere & Company
|
LR35023,00001E5-19-20180308
|
|