Every 250 Hours (S660 and S670)

  1. IMPORTANT:

    BM004610
    BM004610-UN-11FEB16

    H97455
    H97455-UN-30JUL10

    H107149
    H107149-UN-06MAR13

    A - Cap

    B - Drain

    C - Dipstick

    D - Fuel Tank Breather

    Change oil and filter every 100 hours if fuel contains a high sulfur content.

    Change oil and filter every 250 hours if crankcase filled with seasonal viscosity grade oil or John Deere Torq-Gard™.

    If using John Deere Plus-50™ or Plus-50™ II engine oil and a John Deere filter, service interval can be extended by 50 percent. Example: 250 Hours extends to 375 Hours.

    Only to S660 equipped with Tier 3/Stage IIIA Engine and if using John Deere Plus-50™ II engine oil and a John Deere filter, service interval can be extended by 100 percent. Example: 250 Hours extends to 500 Hours1.

    Engine Crankcase Top Load Oil Filter - Remove cap (A) and remove filter. Replace filter and install cap. Tighten cap to specifications.

    ItemMeasurementSpecification
    Oil Filter CapTorque40 N·m (30 lb·ft)



  2. Engine Crankcase Top Load Oil - Open drain (B) to remove oil.

  3. Engine Crankcase Top Load Oil - Remove dipstick (C) to fill and check oil level after filling.

  4. Fuel Tank Breather - Visually inspect fuel tank breather (D). Do not allow debris to collect on breather. Remove fuel tank breather from hose and clean.


Torq-Gard is a trademark of Deere & Company

Plus-50 is a trademark of Deere & Company
1 For more information, See Engine Oil and Filter Service Intervals in Fuels and Lubricants Section.

OU90500,000056B-19-20161128