Header Height Sensing (HydraFlex™ Platforms)
NOTE:

H96245-UN-03MAY10
Header Setup Icons

H109803-UN-12FEB14
Draper/Platform/Belt Pickup Display
A - Automatic Header Height Modes Icon
B - Header Height Sensing Icon
Header setup icon changes based on type of header connected
to machine.
Allows operator to adjust cutterbar ground pressure, or cutterbar
weight, and return to that setting automatically. HydraFlex works
in conjunction with Header Height Sensing to maintain a header position
relative to the ground, follow ground contour, and return to that
position automatically. HydraFlex™ heads use a sensor located
on the right side of the header to measure the hydraulic pressure
used to support the cutterbar.
NOTE: HydraFlex™ does not control cutting height relative
to ground. This is automatically controlled by the height sensing
system and is not adjustable through the active header control dial
when HydraFlex™ is present.
System must be calibrated with each header that is used (see
Calibration Procedures section).
Activation buttons 1, 2 or 3 located on the multi-function lever
are used to select one of the three different programmable HydraFlex™
pressures.
NOTE: If multiple modes are enabled, refer to Activation Button
Mode Combinations in this section for further information.
Enable/Disable System:
Touch or press confirm switch when header setup icon is highlighted.
Touch or press confirm switch when automatic header height modes
icon (A) is highlighted.
Touch or press confirm switch when Header Height Sensing icon
(B) is highlighted.
NOTE: Checkmark appears indicating system is enabled or disappears
indicating system is disabled.
Operation:

H99253-UN-01DEC10

H95079-UN-27JAN10

H109729-UN-29JAN14
A - Header Height Sensing Icon
B - Activation Button Number
C - Pressure Setpoint
D - Header Height Control Dial
E - Bar Graph
F - Numeric Display
G - Header Raise/Lower Switch
System is active when:
-
Properly equipped header is connected to machine.
-
Engine is running.
-
Road transport disconnect switch is in field position.
-
Header Height Sensing system enabled.
-
Header is engaged.
Activate Header Height Sensing (HydraFlex™) by pressing
activation buttons 1, 2 or 3 on multi-function lever.
Activation button number (B) on display indicates which activation
button was selected.
Header Height Sensing icon (A) appears on display indicating
system is active.
To change pressure setpoint (C) of activation buttons, press
desired activation button and adjust pressure using active header
height control dial (D).
Bar graph (E) and numeric display (F) show the pressure setpoint
based on the pressure in the cutterbar on the platform.
NOTE: HydraFlex™ cannot operate independent of Header
Height Sensing in an automatic mode. These systems work together to
control cutterbar weight and header movement.
Turn active header height control dial towards plus (+) symbol
to increase HydraFlex™ pressure and setpoint or towards minus
(-) symbol to lower HydraFlex™ pressure and setpoint.
NOTE: Header lower switch can be set to immediately disable
system until activation button is pressed, see your John Deere dealer
for further information.
Manually adjusting header height with header lower switch (G)
temporarily overrides system until released. Once switch is released,
system returns to automatic mode.
NOTE: Header lower switch can be set to not reactivate system
when header lower switch is pressed, see your John Deere dealer for
further information.
Using header raise switch (G) temporarily deactivates system
until header lower switch is pressed. Once switch is pressed, system
reactivates.
Press activation buttons 1, 2 or 3 to reactivate system or manually
lowering header height with header lower switch (G) reactivates system.
Header automatically moves to preselected pressure.
|
HydraFlex is
a trademark of Deere & Company
|
WM05597,000134E-19-20150706
|
|