BALETRAK PLUS® Monitor-Controller Setup Values and Initial Settings

BALE DIAMETER
Readout Display Range 30.5-63 in. (0.77-1.6 m)
Diameter Adjustment Range 36-60 in. (0.91-1.52 m)
Diameter Initial Settinga 56 in. (1.42 m)
Near Full Size Range 0.5-10.0 in. (0.01-0.25 m)
Near Full Size Initial Settinga 4.5 in. (0.11 m)
Bale Shape Sensitivity Range 1 (slowest)-5 (fastest)
Bale Shape Sensitivity Initial Settinga 3 (medium)
TWINE WRAP
Spacing Range 2-10 in. (0.05-0.25 m)
Spacing Initial Settinga 4 in. (0.10 m)
Number of End Wraps Range
Left-Hand End 0-10 Wraps
Right-hand End 0.6-10 Wraps
Number of End Wraps Initial Settinga 2 Wraps
Left-Hand End Wrap Distance Range 3-10 in. (0.08-0.25 m)
Right-Hand End Wrap Distance Range
457 and 457S 3-10 in. (0.08-0.25 m)
557 2-10 in. (0.05-0.25 m)
End Wrap Distance Initial Setting (Right and Left-Hand)a 4 in. (0.11 m)
Re-Extension Wrap Distance Range 5-20 in. (0.13-0.51 m)
Cinch Wrap Initial Setting (From Left-Hand End) 10 in. (0.25 m)
NET WRAP
Number of Wraps 1.2-5
Number of Wraps Initial Settinga 2
Time Delay Range (From Full-Size Bale Alert to Start of Net Wrap Cycle) 0-8 Seconds
Time Delay Initial Settinga 2 Seconds
VARIABLE CORE DIAMETER
Diameter Adjustment Range 32-56 in. (0.81-1.4 m)
Diameter Initial Settinga 36 in. (0.92 m)
aSettings revert to these values when monitor-controller is reset. (See BALETRAK PLUS® MONITOR-CONTROLLER-RESET TO INITIAL SETTINGS [CH 01] in this section.)

 

OUMX005,0000040 -19-27SEP00-1/1