BALETRAK PLUS® Monitor-Controller Diagnostic and Setup Channels

NOTE: Channel listings and page numbers can be found under Operating Baler with BALETRAK

PLUS ® System or Service-Baler in the Contents or under section "C" in the Index.

CHANNEL NUMBER FUNCTION
1 Return to Initial Settings
3 Adjust Twine Wrap Sensor With Sound
5 Adjust Bale Diameter Sensor With Sound
7 Adjust Right Bale Shape Bar Display and Sensor With Sound
9 Adjust Left Bale Shape Bar Display and Sensor With Sound
10 Test Net Wrap Switch
11 Test Oversize Bale Switch
12 Test Gate Close Switch
13 NOT USED
14 Test Twine or Net Actuator Current
15 Check Tractor Voltage
16 Test Liquid Crystal Display
17 Dry Straw Twine Wrap Program
18 Adjust Re-Extension Wrap Distance and Cinch Wrap
19 NOT USED
20 NOT USED
21 NOT USED
22 NOT USED
23 NOT USED
24 Adjust Bale Shape Sensitivity
25 Adjust Near-Full Indicator
26 Net Wrap Delay
27 NOT USED
The following channels have been programmed to perform adjustments WITHOUT the audible alarm.
CHANNEL NUMBER FUNCTION
2 Adjust Twine Wrap Sensor
4 Adjust Bale Diameter Sensor
6 Adjust Right Bale Shape Bar Display and Sensor
8 Adjust Left Bale Shape Bar Display and Sensor

 

OUMX005,0000041 -19-28SEP00-1/1