Replacing Bale Shape Sensor

1. Engage gate lock and raise tension arm.

2. Turn monitor-controller OFF. Turn tractor key to OFF position. Remove key.

AG,OUMX005,1542 -19-03AUG00-1/5


3. To replace sensor remove rolling thread cap screw (B). Rotate shield (A) away from baler.


A-Shield
B-Rolling Thread Cap Screw

E47621

Right-Hand Side Shown

AG,OUMX005,1542 -19-03AUG00-2/5


4. Disconnect wiring connector (A).


A-Sensor

E48083

Right-Hand Side Shown

AG,OUMX005,1542 -19-03AUG00-3/5


5. Remove parts (A-E).


A-Mounting Strap
B-O-Ring
C-Sensor
D-Washer (2 used)
E-Mounting Screw (2 used)

E48084

AG,OUMX005,1542 -19-03AUG00-4/5


6. Install new sensor in reverse order of removal using the following special instructions:

  • Make sure O-ring is inserted in groove (A).
  • Adjust sensor. (See ADJUSTING BALE SHAPE SENSOR [CHANNELS 07 and 09] in this section.)


A-Groove

E48085

AG,OUMX005,1542 -19-03AUG00-5/5