Setting Tractor Hydraulic Outlets

The tractor must have a minimum of two double-acting selective control valves (SCVs).

If baler is equipped with optional Hydraulic Pickup Lift, the tractor must have an additional SCV. (Three hydraulic circuits total.)

Set tractor hydraulic remote outlets to provide approximately 5 second gate opening time.

For 5000/5010 Series John Deere tractors, joystick control lever detent is in the full forward position. Do

not push lever full forward, so lever returns to neutral when released.

For 6000 and 7000/7010 Series John Deere tractors, adjust SCV lever for no detent, so lever returns to neutral when released.

For 8000 Series John Deere tractors, set detent time at 0. (See Hydraulics and Selective Control Valves section in tractor Operator's Manual.)

AG,OUO6017,1213 -19-22SEP99-1/1