Testing Net Wrap Actuator Current (Channel 018)
NOTE:
Channel 018 allows operator use of EXTEND and RETRACT keys to position net actuator for service.
This test is used to determine the working condition of the actuator through its entire range of operation.
To test actuator (motor and linkage) :
1.
Turn tractor key to ON position. Do not start tractor engine.
2.
Turn monitor-controller ON.
3.
Press and hold COUNTER key (A) while selecting NET mode.
4.
Continue to hold COUNTER key and press PLUS key until "CH 018" appears in digital display.
NOTE:
Current flow readings shown on digital display are relative numbers, not indications of measurable units (amps).
5.
Release COUNTER key; digital display will change to show actuator static current flow reading of "0" to "1".
6.
Use EXTEND and RETRACT keys (B and C) to operate actuator in both directions. Display should show a current flow reading between "1" and "8" while actuator motor is operating during mid stroke (no load).
-
Below normal readings indicate low tractor voltage, or poor or corroded harness connections
-
Above normal readings indicate binding linkage or partially shorted motor windings
-
Current spike reading indicates mechanical obstruction to linkage
NOTE:
Net wrap actuator is at full stroke position when actuator is fully extended.
7.
Continue to operate actuator to full stroke position. Display should show stall (
load
) current reading between "20" and "30".
|