2.
Press and hold COUNTER key (A) while turning monitor-controller ON. Continue to hold COUNTER key and press PLUS key until "CH 012" appears in digital display.
3.
Release key and view reading (Switch Closed Internally).
Diagnostic Channel |
Function |
Switch Closed Reading |
Switch Open Reading |
012 |
Net Wrap Switch |
00 (Zero)-Normal |
012-Net Cutting (Tone) |
4.
Depress lever (B) to open switch internally. View second reading or listen for tone (Switch Open).
5.
If readings are not as shown, Check wire hookup. (See CHECK AND ADJUST NET WRAP SWITCH in this instruction.)
6.
If switch adjustment does not produce normal readings:
a.
Turn monitor-controller OFF. Turn tractor key to OFF position. Remove key.
b.
Check for correct wiring connections.
c.
Check wiring harness for cuts and breaks.
d.
Check harness connectors for damaged (pushed in) terminals.
e.
Check that wires are not shorted to each other or to ground.
f.
Replace switch if necessary.
|