BALETRAK
PLUS
® Monitor-Controller Setup Values and Initial Settings
BALE DIAMETER
Readout Display Range
22-75 in. (0.56-1.9 m)
Diameter Adjustment Range
32-72 in. (0.81-1.83 m)
Diameter Initial Setting
a
66 in. (1.68 m)
Near Full Size Range
0.5-10.0 in. (0.01-0.27 m)
Near Full Size Initial Setting
a
4.5 in. (0.11 m)
Bale Shape Sensitivity Range
1 (slowest) - 5 (fastest)
Bale Shape Sensitivity Initial Setting
a
3 (medium)
TWINE WRAP
Spacing Range
2-10 in. (0.05-0.26 m)
Spacing Initial Setting
a
4 in. (0.10 m)
Number of End Wraps Range
Left-Hand End
0-10 Wraps
Right-Hand End
0.6-10 Wraps
Number of End Wraps Initial Setting
a
2 Wraps
Left-Hand End Wrap Distance Range
3-10 in. (0.08-0.25 m)
Right-Hand End Wrap Distance Range
466 and 466S
3-10 in. (0.08-0.25 m)
566
2-10 in. (0.05-0.25 m)
End Wrap Distance Initial Setting (Right and Left-Hand)
a
4 in. (0.11 m)
NET WRAP
Number of Wraps
1.2-5
Number of Wraps Initial Setting
a
2
Time Delay Range (From Full-Size Bale Alert to Start of Net Wrap Cycle)
0-8 Seconds
Time Delay Initial Setting
a
2 Seconds
VARIABLE CORE DIAMETER
Diameter Adjustment Range
24-67 in. (0.61-1.7 m)
Diameter Initial Setting
a
36 in. (0.92 m)
a
Settings revert to these values when monitor-controller is reset. (See RESETTING BALETRAK PLUS® TO INITIAL SETTINGS in this section.)
BALETRAK
PLUS
is a registered trademark of Deere & Company
AG,OUO6017,1619 -19-03NOV99-1/1