Tractor Convenience Outlet

John Deere 55 Series, 6000, 7000, or 8000 models

Plug BALETRAK PLUS ® into the standard convenience outlet (A) located on side console.


A-Convenience Outlet

RW22076

John Deere 7000 Series Tractor Shown

BALETRAK PLUS is a registered trademark of Deere & Company

EX,566V,S -19-02SEP97-1/3


Other tractor models without a convenience power outlet

Order convenience outlet kit AE50549 from your John Deere dealer. Only this kit should be used to provide a convenience outlet due to its wire size, lack of splices, and the circuit breaker included in kit. When installing kit, attach the power and ground wires directly to the battery terminal clamp bolts, only.

IMPORTANT: The BALETRAK PLUS ® monitor-controller is polarity sensitive. The red lead from the monitor-controller power input MUST be installed on the positive (+) side of a 12 volt system. Failure to do so will cause failure of the internal 30 amp fuse in the monitor-controller.

E39605

EX,566V,S -19-02SEP97-2/3


Other tractor models with a convenience power outlet

Complete the following check to determine if the convenience power outlet provides adequate power for the BALETRAK PLUS ® system.

1. With tractor engine running, press and hold DEERE key (A). Set monitor-controller selector switch to TWINE mode. Monitor-controller ON.

2. Continue to hold DEERE key (A) and press PLUS key until "CH 15" appears in digital display.

3. Release DEERE key (A). View tractor voltage readout.

4. Using the EXTEND key, extend the twine actuator slightly.

5. Push and hold the RETRACT key until the actuator stalls out in the cutoff position and note the voltage displayed. Avoid holding the RETRACT key for more than 5 seconds after the actuator stalls out.

6. If voltage is less than 9.7, install convenience outlet kit AE50549. Order from your John Deere dealer.

IMPORTANT: The BALETRAK PLUS ® monitor-controller is polarity sensitive. The red lead from the monitor-controller power input MUST be installed on the positive (+) side of a 12 volt system. Failure to do so will cause failure of the internal 30 amp fuse in the monitor-controller.

NOTE: Only this kit should be used to provide a convenience outlet due to its wire size, lack of splices , and the circuit breaker included in the kit. When installing The kit, attach power and ground wires directly to the battery terminal clamp bolts only.

E47602


A-DEERE Key

EX,566V,S -19-02SEP97-3/3