Releasing Accumulator-Float Pressure

causym CAUTION: To prevent personal injury or machine damage, release accumulator float pressure only when the platform is on the ground.

Lower platform to the ground.

AG,OUO6038,1187 -19-11OCT99-1/2


To release accumulator/float pressure, turn knob (A) counterclockwise opening the valve.

To close the valve, turn knob (A) clockwise.


A-Knob

E43039

AG,OUO6038,1187 -19-11OCT99-2/2