Engine - Use Coolant Test Strips to Check Coolant

TS281
TS281-UN-15APR13

LX1057332
LX1057332-UN-28OCT13

A - Expansion Tank Cap

B - Max. Marking of the Expansion Tank


CAUTION: Do not open cap (A) of expansion tank before coolant temperature is below boiling point! First unfasten the cap to release pressure, then remove cap completely.

John Deere COOL-GARD™ II Premix and Concentrate are maintenance-free coolants for up to 6 years or 6000 hours of operation, provided that the cooling system is topped up using only John Deere COOL-GARD II Premix. Test the coolant condition annually with coolant test strips designed for use with John Deere COOL-GARD™ II coolants. If the test strip chart indicates that additional coolant is required, add John Deere COOL-GARD II EXTENDER as instructed.

  1. Open the hood.

  2. First unfasten cap (A) and then take it off.

  3. Testing the coolant using COOL-GARD™ II three-way test strips (TY26605), available from your John Deere™ dealer.

  4. NOTE: Follow instructions provided with the test strips when testing coolant.

    Add TY26603 COOL-GARD™ II Coolant Extender (available from your John Deere™ dealer) as indicated by the color matrix on reader card in test strip pack. If tank is too full, drain a small amount of coolant from system before coolant conditioner is added.

    NOTE: Visually check cap gasket for sealing effectiveness. A properly functioning gasket should have the imprint of the mating surface but no apparent scratches or leak paths.

  5. Add coolant up to the max. mark (B), if necessary.

  6. Put cap (A) back on and close the hood.

OULXA64,0002671-19-20131025