TIA - Requirements for Electronic Selective Control Valves
Before transferring control to the implement, perform all necessary
steps to prepare the implement as indicated in the operator's manual
of the implement.
While operating, implement has the ability to:
-
Control SCVs during operations.
-
Change SCV flow rate up to operator set limit.
-
Move the SCVs in all of their 4 positions (retract, extend,
neutral, and float).
NOTE: Using tractor's CommandCenter, operator sets SCV flow
limit which cannot be exceeded by implement.
The following preconditions have to be met before transferring
implement control.
-
Operator sitting on seat.
-
SCVs are functional.
-
SCV control levers in neutral position.
-
SCVs are not locked (transport lock).
Transfer control using AutoTrac resume switch or TIA resume softkey as presented in
the implement Operator's Manual.
To withdraw control:
-
Actuate specific SCV lever.
-
Lock SCVs (transport lock).
-
Actuate SCV fender switch (if equipped).
NOTE: Unless the implement is authorized to adjust SCV flow
when the tractor is stationary, the tractor will prevent SCV flow
adjustments when stationary. The implement is however, allowed to
stop oil flow.
|
AutoTrac is a trademark of Deere & Company
|
OULXA64,00026B8-19-20110118
|
|