CUSTOMER CHANNELS |
|
| Channel Number |
Contents |
Remarks |
| 001 |
Reset all settings to factory Initial Settings |
See factory initial settings |
| 002 |
Dry Straw Twine Wrap Program |
Plus key turns ON, minus turns OFF |
| 003 |
Re-extension Twine tying Program |
Plus key turns on and increases, minus turns off and decreases (OFF, 8.0, 16.0, 24.0) |
| 004 |
Cinch Wrap Twine tying Program |
Plus key turns ON, minus turns OFF |
| 005 |
Calibration of bale size Diameter Sensor |
At value 208 for 467-567, 173 for 457-557 |
| 006 |
Net Wrap Delay |
Default value will be 2 (0-8) seconds |
| 007 |
Calibration of right belt tension sensor |
At value 176 |
| 008 |
Measurement units |
Will display Sl for metric and En for English |
| 009 |
Calibration of left belt tension sensor |
At value 176 |
| 010 |
Offset of near full alarm |
Initial setting is 4.5 (0.5-10.0) inches |
| 011 |
Bale shape sensitivity |
Initial setting is 3 (1-5) |
| 012 |
Test Of The Net Switch |
Released=12 & tone, depressed=00 |
| 013 |
Test Of the Oversize Switch |
Released=12, depressed=00 & tone |
| 014 |
Test Of The Right Gate Latch Switch |
Released=12 & tone, depressed=00 |
| 015 |
Test Of The Left Gate Latch Switch |
Released=12 & tone, depressed=00 |
| 016 |
PTO RPM sensor output |
Read the speed |
| 017 |
Pick up RPM sensor output |
Read the speed |
| 018 |
Test of the Current in the actuators |
Read the current |
| 019 |
Test of system voltage |
Read the voltage |
| 020 |
Test of the LCD screen |
Display all segments |
| 029 |
Twine Arm Calibration Value |
|
| 033 |
Delay of Twine Eject Icon |
Default 0 (0-10) Seconds |