Bleeding Platform Lift Circuit
This procedure is necessary when left-hand cylinder is setting
down on cylinder lock and right-hand cylinder is fully extended. If
left-hand side of machine does not raise up, bleed oil from right-hand
cylinder according to following instructions.
CAUTION:

X9811-UN-23AUG88
Escaping fluid under pressure can penetrate the skin causing
serious injury. Avoid the hazard by relieving pressure before disconnecting
hydraulic or other lines. Tighten all connections before applying
pressure. Search for leaks with a piece of cardboard. Protect hands
and body from high pressure fluids.If an accident occurs,
see a doctor immediately. Any fluid injected into the skin must be
surgically removed within a few hours or gangrene may result. Doctors
unfamiliar with this type of injury should reference a knowledgeable
medical source. Such information is available from Deere & Company
Medical Department in Moline, Illinois, U.S.A.
-
Engage right-hand cylinder lock.
-
Wrap a rag around right-hand cylinder fitting.
-
Loosen fitting and release oil until right-hand cylinder rests
on cylinder lock.
-
Tighten fitting.
-
Raise platform and disengage cylinder locks.
-
Lower platform.
|