BALETRAK™ Pro Monitor-Controller Error Codes

Error Code Description Solution
E0 01 Erratic supply voltage when actuator operating Check Battery
Check Alternator
Check wires and connections
see Channel 19 in Service section
E0 02 Low Voltage Check Alternator
Check wires and connections perform voltage test, see Testing Tractor Outlet Voltage, Channel 19, in Service Section
E0 03 High Voltage Check alternator
See Channel 19 in Service section
E1 02 Bale size sensor disconnected or shorted to ground Check wires and connectors
Check sensor
E1 03M Bale size sensor shorted to power Check wires and connectors
Check sensor
E1 04 Bale size sensor below working range Check sensor adjustment , see Channel 5 in Service section
E1 05 Bale size sensor above working range Check sensor adjustment , see Channel 5 in Service section
E1 12 Right bale shape sensor shorted to ground Check wire and connectors
Check sensor
E1 13 Right bale shape sensor shorted to power Check wire and connectors
Check sensor
E1 14 Right bale shape sensor below working range Check sensor adjustment , see Channel 7 in Service section
E1 15 Right bale shape sensor above working range Check sensor adjustment , see Channel 7 in Service section
E1 22 Left bale shape sensor shorted to ground Check wire and connectors
Check sensor
E1 23 Left bale shape sensor shorted to power Check wire and connectors
Check sensor
E1 24 Left bale shape sensor below working range Check sensor adjustment , see Channel 9 in Service section
E1 25 Left bale shape sensor above working range Check sensor adjustment , see Channel 7 in Service section
E2 01 Twine actuator disconnected Check wires and connectors
E2 02 Twine actuator faulty Check twine actuator using extend/retract switches
Check twine actuator using by-pass switch
E2 03 Timeout error during twine wrapping cycle Check for obstruction or binding
E2 04 Twine actuator harness shorted to battery Check wires and connectors
Check twine actuator
E2 05 Twine actuator harness shorted to ground Check wires and connectors
Check sensor

 

OUO6085,0000142 -19-30JUN08-1/3


Error Code Description Solution
E2 11 Net actuator disconnected Check wires and connectors
E2 12 Net actuator faulty Using channel 19, check net actuator using extend/retract switches
E2 13 Time-out error during net wrapping cycle Check for obstruction or binding
E2 14 Net actuator harness shorted to battery Check wires and connectors
Check net actuator
E2 15 Net actuator harness shorted to ground Check wires and connectors
Check net actuator
E2 21 Variable core valve disconnected Check wires and connectors
Check variable core valve solenoid
E2 22 Variable core valve shorted to power Check wires and connectors
Check variable core valve solenoid
E2 23 Variable core valve shorted to ground Check wires and connectors
Check variable core valve solenoid
E3 01 Open circuit PTO RPM sensor Check wires, connectors, and sensor for damage.
Check sensor readout on channel 16, See Wrap cycle without PTO engaged
E3 02 PTO sensor less than minimum speed Check sensor adjustment and sensor readout, See sensor readout on channel 17 for approximately 310 RPM. Speed should not vary more than 5 RPM
E3 03 PTO sensor exceeds maximum speed Check sensor adjustment and sensor readout, See sensor readout on channel 17 for approximately 310 RPM. Speed should not vary more than 5 RPM
E4 01 Net did not wrap bale See net section of troubleshooting
E4 02 Net did not cut See net section of troubleshooting
E4 11 Right gate switch always open Check right gate switch adjustment and function. See right gate switch adjustment and testing, Channel 14 in Service section
E4 12 Right gate switch always closed Check right gate switch adjustment and function. See right gate switch adjustment and testing, Channel 14 in Service section
E4 3 Oversize switch always open Check oversize switch adjustment and function. See oversize bale switch adjustment and testing, Channel 13 in Service section
E5 01 Open circuit, negative sensor circuit Check sensor wires, connectors, and sensors
E5 02 Grounded circuit, negative sensor circuit Check sensor wires, connectors, and sensors
E5 03 Shorted circuit, negative sensor circuit Check sensor wires, connectors, and sensors
E5 11 Open circuit, positive sensor circuit Check sensor wires, connectors, and sensors

 

OUO6085,0000142 -19-30JUN08-2/3


E5 12 Grounded circuit, positive sensor circuit Check sensor wires, connectors, and sensors
E5 13 Shorted circuit, positive sensor circuit Check sensor wires, connectors, and sensors

 

OUO6085,0000142 -19-30JUN08-3/3