Symptom |
Problem |
Solution |
Bale density gauge reading in red.
|
Tractor selector valve (SCV) not in neutral position while baling.
|
Move hydraulic lever to neutral while baling.
|
|
Defective density gauge.
|
Replace. (See your John Deere dealer.)
|
|
Adjustable relief valve set too high.
|
Adjust valve. (See ADJUSTING BALE DENSITY in Operating the Baler section.)
|
|
Defective adjustable relief valve.
|
Replace valve. (See your John Deere dealer.)
|
Gate opens while baling.
|
Tension gate cylinder extends when gate is closed and tractor selector control valve (SCV) is in neutral.
|
Air in hydraulic system. Open and close gate several times to remove air.
Faulty relief valve. (See your John Deere dealer.)
|
|
Tractor selector control valve (SCV) leaking.
|
Repair or replace. (See your John Deere dealer.)
|
|
Internal leak in baler hydraulic system.
|
Repair. (See your John Deere dealer.)
|
Gate will not close or lock.
|
Adjustable relief valve setting too low.
|
Turn adjustable relief valve knob clockwise to increase relief setting. (See ADJUSTING BALE DENSITY in Operating the Baler section.)
|
|
Obstruction between gate and frame.
|
Remove obstruction
|
|
Hydraulic flow of tractor too low.
|
Adjust tractor hydraulic flow. (See your tractor Operator's manual.)
Add orifice to bale tensioning valve. (See INSTALLING ORIFICE IN TRACTORS WITH LOW HYDRAULIC FLOW in Service-Baler section.)
|
|
Orifice at quick-disconnect (SCV) end of small diameter hose not installed correctly.
|
Reverse direction of orifice.
|