Symptom |
Problem |
Solution |
Automatic twine cycle does not function. STOP indicator displays and alarm sounds.
|
Defective gate closed switch.
|
Replace switch. (See REPLACING GATE CLOSED SWITCH in Service-Baler section).
|
|
Incorrect gate closed switch adjustment.
|
Adjust gate close switch. (See procedure in Service-Baler section.)
|
|
Gate not closed completely and does not activate one gate switch.
|
Remove hay buildup from gate area.
Operate baler at tractor rated PTO speed when closing the gate.
|
|
Released selective control valve too soon after closing gate.
|
Continue to hold selective control valve 2 seconds after gate closes.
|
|
Gate twisted and does not close completely.
|
See your John Deere dealer.
|
|
Manual BYPASS wiring harness connected.
|
Return twine actuator connector to NORMAL OPERATION connector. (See USING BYPASS SWITCH [TWINE WRAP ONLY] in Operating the Baler section.)
|
Twine arm actuator stops at full extension and will not retract.
|
Monitor-controller set for incorrect baler model.
|
Change monitor-controller setting. (See CHANGING BALER MODEL PROGRAM in Operating the Baler - BaleTrak Pro monitor system section.)
|
|
|
Inspect wiring harness. Repair or replace.
|
Twine spacing to edge of bale is greater than monitor-controller setting.
|
Incorrect mechanical twine guide setting.
|
Adjust mechanical twine guide. (See SETTING TWINE SPACING in Operating the Baler section.)
|
Number of end wraps is different than monitor-controller setting.
|
Missing or bent twine guide rod.
|
Replace or straighten rod.
|
|
Not operating at tractor rated PTO speed (without slip clutch alert).
|
Operate at rated PTO speed or at a consistent speed. A constant speed less than rated PTO speed will require a different monitor-controller setting.
|