CUSTOMER and SETUP CHANNELS |
|
| Channel Number |
Contents |
Remarks |
| 001 |
Reset All Settings to Factory Initial Settings |
See factory initial settings |
| 002 |
Dry Straw Twine Wrap Program |
Plus key turns ON, minus turns OFF |
| 003 |
Re-extension Twine Tying Program |
Plus key turns on and increases, minus turns off and decreases (OFF, 8.0, 16.0, 24.0) |
| 004 |
Cinch Wrap Twine Tying Program |
Plus key turns ON, minus turns OFF |
| 005 |
Calibration of Bale Size Diameter Sensor |
At value 208 |
| 006 |
Net Wrap Delay |
Default value will be 2 (0-8) seconds |
| 007 |
Calibration of Right Belt Tension Sensor |
At value 176 |
| 008 |
Measurement Units |
Will display Sl for metric and En for English |
| 009 |
Calibration of Left Belt Tension Sensor |
At value 176 |
| 010 |
Offset of Near Full Alarm |
Initial setting is 4.5 (0.5-10.0) inches |
| 011 |
Bale Shape Sensitivity |
Initial setting is 3 (1-5) |
| 012 |
Test of Net Switch |
Released=12 & tone, depressed=00 |
| 013 |
Test of Oversize Switch |
Released=12, depressed=00 & tone |
| 014 |
Test of Right Gate Latch Switch |
Released=12 & tone, depressed=00 |
| 015 |
Test of Left Gate Latch Switch |
Released=12 & tone, depressed=00 |
| 016 |
PTO RPM Sensor Output |
Read the speed |
| 017 |
Pickup RPM Sensor Output |
Read the speed |
| 018 |
Test of Current in Actuators |
Read the current |
| 019 |
Test of System Voltage |
Read the voltage |
| 020 |
Test of LCD Screen |
Display all segments |
| 029 |
Twine Arm Calibration Value |
|
| 033 |
Delay of Twine Eject |
Default 0 (0-10) Seconds |
| 201 |
Baler Model |
4xx to 5xx |
| 202 |
Twine |
0= OFF, 1= ON |
| 203 |
Net |
0= OFF, 1= ON |
| 204 |
PTO Sensor |
0= OFF, 540 or 1000= ON |
| 205 |
Pickup Sensor |
0= OFF, 310= ON |
| 206 |
PTO Sensor Calibration |
24= Number of Fins on PTO Clutch |