BaleTrak Pro Monitor-Controller Setup Values and Initial Settings
|
|
| BALE DIAMETER |
| Readout Display Range |
57-191 cm (22.5-75 in.) |
| Diameter Adjustment Range |
81-183 cm (32-72 in.) |
| Diameter Initial Settinga |
168 cm (66 in.) |
| Near Full Size Range |
1-27 cm (0.5-10.0 in.) |
| Near Full Size Initial Settinga |
11 cm (4.5 in.) |
| Bale Shape Sensitivity Range |
1 (slowest) - 5 (fastest) |
| Bale Shape Sensitivity Initial Settinga |
3 (medium) |
| Spacing Range |
2-26 cm (1-10 in.) |
| Spacing Initial Settinga |
10 cm (4 in.) |
| Number of End Wraps Range |
| Left-Hand End |
0-5 Wraps |
| Right-hand End |
0.5-5.0 Wraps |
| Number of End Wraps Initial Settinga |
2 Wraps |
| Left-Hand, Right-Hand End Wrap Distance Range |
8-26 cm (3-10 in.) |
| End Wrap Distance Initial Setting (Right and Left-Hand)a |
10 cm (4 in.) |
| Re-Extension Wrap Distance Range |
OFFa, 20, 40, 60 cm (8, 16, 24 in.) |
| Cinch Wrap Initial Setting (From Left-Hand End) |
OFFa, 25 cm (10 in.) |
| Dry Straw |
OFFa, ON |
| Delay of Twine Eject |
0-10 Seconds |
| Delay of Twine Eject, Initial Setting |
0 Seconds |
| NET WRAP |
| Number of Wraps |
1.5-10.0 |
| Number of Wraps Initial Settinga |
2 |
| Time Delay Range (From Full-Size Bale Alert to Start of Net Wrap Cycle) |
0-8 Seconds |
| Time Delay Initial Settinga |
2 Seconds |
| aSettings revert to these values when monitor-controller is reset. (See BaleTrak™ Pro MONITOR-CONTROLLER-RESET TO INITIAL SETTINGS [CH 001] in this section.) |
|
BaleTrak is a registered trademark of Deere & Company
|
PP98408,00000EC -19-10SEP09-1/2
|
| VARIABLE CORE DIAMETER |
| Diameter Adjustment Range |
61-173 cm (24-68 in.) b |
| Diameter Initial Settinga |
91 cm (36 in.) |
| aSettings revert to these values when monitor-controller is reset. (See BaleTrak™ Pro MONITOR-CONTROLLER-RESET TO INITIAL SETTINGS [CH 001] in this section.) |
| b10 cm (4 in.) below size setting. |
|
|