| E0 01 |
Erratic supply voltage when actuator operating |
Check Battery and Alternator Check wires and connections see Channel 19 in Service section |
| E0 02 |
Low Voltage |
Check Alternator Check wires and connections perform voltage test, see Testing Tractor Outlet Voltage, Channel 19, in Service Section |
| E0 03 |
High Voltage |
Check alternator See Channel 19 in Service section |
| E1 02 |
Bale size sensor disconnected or shorted to ground |
Check wires and connectors Check sensor |
| E1 03 |
Bale size sensor shorted to power |
Check wires and connectors Check sensor |
| E1 04 |
Bale size sensor below working range |
Check sensor adjustment , see Channel 5 in Service section |
| E1 05 |
Bale size sensor above working range |
Check sensor adjustment , see Channel 5 in Service section |
| E1 12 |
Right bale shape sensor shorted to ground |
Check wire and connectors Check sensor |
| E1 13 |
Right bale shape sensor shorted to power |
Check wire and connectors Check sensor |
| E1 14 |
Right bale shape sensor below working range |
Check sensor adjustment , see Channel 7 in Service section |
| E1 15 |
Right bale shape sensor above working range |
Check sensor adjustment , see Channel 7 in Service section |
| E1 22 |
Left bale shape sensor shorted to ground |
Check wire and connectors Check sensor |
| E1 23 |
Left bale shape sensor shorted to power |
Check wire and connectors Check sensor |
| E1 24 |
Left bale shape sensor below working range |
Check sensor adjustment , see Channel 9 in Service section |
| E1 25 |
Left bale shape sensor above working range |
Check sensor adjustment , see Channel 7 in Service section |
| E2 01 |
Twine actuator disconnected |
Check wires and connectors |
| E2 02 |
Twine actuator faulty |
Check twine actuator using extend/retract switches Check twine actuator using by-pass switch |
| E2 03 |
Timeout error during twine wrapping cycle |
Check for obstruction or binding |
| E2 04 |
Twine actuator harness shorted to battery |
Check wires and connectors Check twine actuator |
| E2 05 |
Twine actuator harness shorted to ground |
Check wires and connectors Check sensor |
| E2 11 |
Net actuator disconnected |
Check wires and connectors |
| E2 12 |
Net actuator faulty |
Using channel 19, check net actuator using extend/retract switches |
| E2 13 |
Timeout error during net wrapping cycle |
Check for obstruction or binding |
| E2 14 |
Net actuator harness shorted to battery |
Check wires and connectors Check net actuator |
| E2 15 |
Net actuator harness shorted to ground |
Check wires and connectors Check net actuator |
| E2 21 |
Variable core valve disconnected |
Check wires and connectors Check variable core valve solenoid |
| E2 22 |
Variable core valve shorted to power |
Check wires and connectors Check variable core valve solenoid |
| E2 23 |
Variable core valve shorted to ground |
Check wires and connectors Check variable core valve solenoid |
| E3 01 |
Open circuit PTO RPM sensor |
Check wires, connectors, and sensor for damage. Check sensor readout on channel 16, See Wrap cycle without PTO engaged |
| E3 02 |
PTO sensor less than minimum speed |
Check sensor adjustment and sensor readout, See sensor readout on channel 17 for approximately 310 rpm. Speed should not vary more than 5 rpm |
| E3 03 |
PTO sensor exceeds maximum speed |
Check sensor adjustment and sensor readout, See sensor readout on channel 17 for approximately 310 rpm. Speed should not vary more than 5 rpm |
| E4 01 |
Net did not wrap bale |
See net section of troubleshooting |
| E4 02 |
Net did not cut |
See net section of troubleshooting |
| E4 11 |
Right gate switch always open |
Check right gate switch adjustment and function. See right gate switch adjustment and testing, Channel 14 in Service section |
| E4 12 |
Right gate switch always closed |
Check right gate switch adjustment and function. See right gate switch adjustment and testing, Channel 14 in Service section |
| E4 21 |
Left gate switch always open |
Check left gate switch adjustment and function. See right gate switch adjustment and testing, Channel 15 in Service section |
| E4 22 |
Left gate switch always closed |
Check left gate switch adjustment and function. See right gate switch adjustment and testing, Channel 15 in Service section |
| E4 31 |
Oversize switch always open |
Check oversize switch adjustment and function. See oversize bale switch adjustment and testing, Channel 13 in Service section |
| E5 01 |
Open circuit, negative sensor circuit |
Check sensor wires, connectors, and sensors |
| E5 02 |
Grounded circuit, negative sensor circuit |
Check sensor wires, connectors, and sensors |
| E5 03 |
Shorted circuit, negative sensor circuit |
Check sensor wires, connectors, and sensors |
| E5 11 |
Open circuit, positive sensor circuit |
Check sensor wires, connectors, and sensors |
| E5 12 |
Grounded circuit, positive sensor circuit |
Check sensor wires, connectors, and sensors |
| E5 13 |
Shorted circuit, positive sensor circuit |
Check sensor wires, connectors, and sensors |