Baler won't feed; Hay plugged at feed opening.
|
Bale density is too high.
|
Check relief valve. Replace if defective. (See your John Deere dealer.)
|
|
Gate opens while baling due to internal leakage in system component(s).
|
Repair or replace leaking component. (See your John Deere dealer.)
|
Bale sticks in chamber.
|
New baler.
|
Follow break-in instructions in Operating the Baler section.
|
|
Bale density too high.
|
Check relief valve. Replace if defective. (See your John Deere dealer.)
|
|
Damp crop or "gummy" buildup on sidesheets.
|
Clean sidesheets.
|
|
Excessive sidesheet friction.
|
Check straitness and straighten front sidesheets of baler if needed. (See your John Deere dealer.)
|
Bale density too low.
|
Faulty tension/gate cylinder.
|
Repair cylinder if leaking. (See your John Deere dealer.)
|
|
Faulty relief valve.
|
Check relief valve. Replace if defective. (See your John Deere dealer.)
|
|
Damaged O-rings and/or backup rings on relief or check valves.
|
Replace. (See your John Deere dealer.)
|
|
Damaged seat or poppet in relief or check valves.
|
Replace. (See your John Deere dealer.)
|
|
Foreign material keeping check or relief valve poppet from seating.
|
Clean or replace. (See your John Deere dealer.)
|
|
Dirty hydraulic oil in tractor.
|
Change tractor filter and/or oil.
|
Symptom |
Problem |
Solution |
Gate opens while baling.
|
Tension/gate cylinder extends when gate is closed and tractor selector control valve (SCV) is in neutral.
|
Air in hydraulic system. Open and close gate several times to remove air.
|
|
|
Faulty relief valve. Replace. (See your John Deere dealer.)
|
|
Tractor selector control valve (SCV) leaking.
|
Repair or replace. (See your John Deere dealer.)
|
|
Internal leak in baler hydraulic system.
|
Repair. (See your John Deere dealer.)
|
Gate will not close or closes erratically.
|
Obstruction between gate and frame.
|
Remove obstruction.
|
|
Crop buildup on belts.
|
Remove buildup. Operate PTO while closing gate.
|
|
One or both orifices (located near quick-disconnect end of hoses) not installed correctly.
|
Reverse direction of orifice(s).
|
|
Hydraulic flow of tractor too low.
|
Adjust tractor hydraulic flow. (See your tractor Operator's manual.)
|
|
Crop build-up on belts.
|
Remove buildup. Operate PTO while closing gate.
|