Twine arms move too slow from left to right (more than 9 seconds).
|
Flow valve setting too low.
|
Adjust flow valve to increase flow.
|
|
Dirt in flow valve.
|
Clean and flush valve.
|
|
Flow valve is installed backwards.
|
See your John Deere dealer.
|
|
Tractor hydraulic fluid dirty or dirt in cylinder port screen or orifice.
|
Flush baler hydraulic system. Change tractor filter and/or oil.
|
|
|
Clean and flush cylinder.
|
|
Internal cylinder leakage.
|
Install seal kit or replace cylinder. (See your John Deere dealer.)
|
|
Plugged or partially plugged orifice at base end of twine arm cylinder.
|
Remove and clean orifice.
|
|
Incorrect orifice size in hydraulic cylinder.
|
Replace orifice. (See your John Deere dealer.)
|
Twine arms will not return to "home" position.
|
Flow valve closed too far.
|
Open flow valve.
|