Adjusting Tractor Hydraulic Outlets
The tractor must have two double-acting selective control valves (SCV); one for gate control and one for manual hydraulic twine wrap. Only one SCV is needed when baler is equipped with optional Auto-Tie feature.
NOTE:
Adjust hydraulic flow with a bale in chamber and hot oil.
NOTE:
Check times with no bale in chamber and hot oil.
Adjust tractor hydraulic remote outlets to provide approximately 5 second gate opening time.
For 6000 and 7000 Series John Deere tractors, adjust SCV lever for no detent, so lever returns to neutral when released.
For 8000 Series John Deere tractors, set detent time to 0. (See Hydraulics and Selective Control Valves section in tractor operator's manual.)
|