Monitor-Controller LCD display and switches do not work.
|
Monitor-controller connection to tractor is unplugged.
|
Plug in connection.
|
|
|
Monitor-controller was hooked up with reverse polarity.
|
Check polarity of 12 volt power supply.
|
|
Twine arm actuator does not function. Stop indicator displays. Alarm does not sound.
|
Twine arm actuator failed.
|
Replace actuator. (See your John Deere dealer.)
Inspect wiring harness and repair or replace.
|
|
|
Twine arm wedged against back side of knife.
|
Use monitor-controller RETRACT key and retract twine arm. Clean and lubricate knife pivot.
|
|
Twine arm actuator does not function. Stop indicator displays and alarm sounds.
|
Twine arm actuator failed.
|
Replace actuator. (See your John Deere dealer.)
Inspect wiring harness and repair or replace.
|
|
|
Twine arm wedged against back side of knife.
|
Use monitor-controller RETRACT key and retract twine arm. Clean and lubricate knife pivot.
|
|
Twine actuator does not complete its travel. STOP indicator displays and alarm sounds.
|
Twine arm travel restricted by foreign object or hay buildup.
|
Inspect and remove blockage.
|
|
STOP indicator is displayed on monitor-controller when activated.
|
Twine/net actuator disconnected.
|
Check actuator connectors.
|
|
|
Wiring is loose or cut.
|
Check wiring harness connector for breaks.
|
| Symptom |
Problem |
Solution |
|
Automatic twine cycle does not function. STOP indicator displays and alarm sounds.
|
Defective gate latch switch.
|
Replace switch. (See your John Deere dealer.)
|
|
|
Incorrect gate latch switch adjustment.
|
Adjust gate latch switches. (See procedure in Service-Baler section.)
|
|
|
Gate not closed completely and does not activate one gate switch.
|
Remove hay buildup from gate area.
Operate baler at tractor rated PTO speed when closing the gate.
|
|
|
Released selective control valve too soon after closing gate.
|
Continue to hold selective control valve 2 seconds after gate closes.
|
|
|
Gate twisted and does not close completely.
|
See your John Deere dealer.
|
|
|
Manual BYPASS wiring harness connected.
|
Return twine actuator connector to NORMAL OPERATION connector. (See USING BYPASS SWITCH [TWINE WRAP ONLY] in Operating the Baler section.)
|
|
Twine arm actuator stops at full extension and will not retract.
|
Monitor-controller set for incorrect baler model.
|
Change monitor-controller setting. (See CHANGING BALER MODEL PROGRAM in Operating Baler - BaleTrak Pro Monitor System section.)
|
|
|
|
Inspect wiring harness. Repair or replace.
|
|
Twine spacing to edge of bale is greater than monitor-controller setting.
|
Incorrect mechanical twine guide setting.
|
Adjust mechanical twine guide. (See SETTING TWINE SPACING in Operating the Baler section.)
|
| Symptom |
Problem |
Solution |
|
Number of end wraps is different than monitor-controller setting.
|
Incorrect mechanical twine guide adjustment.
|
Adjust mechanical twine guide. (See SETTING TWINE SPACING in Operating the Baler section.)
|
|
|
Not operating at tractor rated PTO speed.
|
Operate at rated PTO speed or at a consistent speed. A constant speed less than rated PTO speed will require a different monitor-controller setting.
|
|
Erratic twine spacing. (Also refer to Automatic Twine Spacing "Twine spacing not consistent" in this section.)
|
Twine catching on foreign object or compressor rods.
|
Inspect and remove blockage or adjust compressor rods. (See ADJUSTING COMPRESSOR RACK ASSEMBLY [REGULAR PICKUP] in Operating the Baler section.)
|
|
|
Incorrect monitor-controller settings.
|
Reset to factory initial settings. (See procedures in Operating the Baler section.)
|
|
|
Not operating at tractor rated PTO speed.
|
Operate at rated PTO speed or at a consistent speed. A constant speed less than rated PTO speed will require a different monitor-controller setting.
|
|
|
Distance between twine arms incorrect for monitor-controller setting.
|
Set twine arm spacing for monitor-controller setting. (See SETTING TWINE SPACING in Operating the Baler section.)
|
|
|
|
Inspect wiring harness. Repair or replace.
|
| Symptom |
Problem |
Solution |
|
Net wrap indicator and alarm activates.
|
Knife did not cut the net wrap material.
|
Adjust brake. (See ADJUSTING NET WRAP STRETCH in Service-Net Wrap section.)
Sharpen net wrap cutoff knife. (See procedure in Service-Net Wrap section.)
|
|
|
Incorrect net wrap switch adjustment.
|
Adjust switch. (See procedure in Service-Net Wrap section.)
|
|
|
Net wrap switch actuator lever not free to rotate.
|
Check actuator lever for obstruction or corrosion in hinged area.
|
|
Twine or net wrapping settings not consistent with different bale sizes.
|
Not operating at tractor rated PTO speed.
|
Operate at rated PTO speed or a consistent speed. A constant speed less than rated PTO speed will require a different monitor-controller setting.
|
|
|
Incorrect bale diameter sensor adjustment.
|
Adjust sensor. (See ADJUSTING BALE DIAMETER SENSOR in Service-Baler section.)
|
|
Bale shape is inconsistent with monitor-controller reading.
|
Operator not following recommended procedure.
|
See INTERPRETING BALE SHAPE INDICATORS in Operating the Baler section.
|
|
|
Incorrect bale shape bar and sensor adjustments.
|
Adjust bale shape bar display and bale shape sensors. (See procedures in Service-Baler section.)
|
|
|
Bale shape sensors failed.
|
Replace sensors. (See procedure in Service-Baler section.)
|
|
|
Broken bale shape sensor arm spring.
|
Replace spring.
|
| Symptom |
Problem |
Solution |
|
Bale size inconsistent with monitor-controller setting.
|
Incorrect bale diameter sensor adjustment.
|
Adjust bale diameter sensor. (See procedure in Service-Baler section.)
|
|
|
Bale diameter sensor failed.
|
Replace sensor. (See procedure in Service-Baler section.)
|
|
|
Tension arm twisted from baling with gate lock lever in LOCKED position.
|
Replace tension arm. (See your John Deere Dealer.) (See CHECKING GATE LOCK VALVE INTERLOCK LEVER ADJUSTMENT in Preparing Baler section.)
|
|
Near-full size indicator does not display on monitor-controller.
|
Bale diameter sensor failed.
|
Replace sensor. (See procedure in Service-Baler section.)
|
|
Bales are not dense.
|
Variable core feature is activated.
|
Turn variable core off.
|
|
|
Variable core set for too large of diameter.
|
Reduce variable core diameter setting or turn off feature.
|
|
|
Variable core solenoid failed.
|
Replace solenoid. (See your John Deere dealer.)
|
|
|
Bale diameter sensor failed.
|
Replace sensor. (See procedure in Service-Baler section.)
|
|
|
Incorrect bale diameter sensor adjustment.
|
Adjust bale diameter sensor. (See procedure in Service-Baler section.)
|
|
Gate open indicator is on when gate is closed.
|
Incorrect gate latch switch adjustment.
|
Adjust switch(es). (See ADJUSTING GATE LATCH SWITCHES in Service-Baler section.)
|
|
|
Defective gate latch switch(es).
|
Replace switch(es). (See your John Deere dealer.)
|
| Symptom |
Problem |
Solution |
|
GATE CLOSED indicator is not displayed after attempting to close gate; STOP indicator may flash and buzzer may sound.
|
Gate did not close because gate lock engaged.
|
Unlock gate.
|
|
|
Gate not fully closed due to an obstruction or twisted condition.
|
Remove obstruction or straighten gate.
|
|
|
Belts pinched between lower gate roll and axle tube.
|
Raise gate fully and close gate at full tractor rpm. If tractor has low hydraulic flow, install orifice. (See INSTALLING ORIFICE IN TRACTORS WITH LOW HYDRAULIC FLOW in Service-Baler section.)
Operate PTO while closing.
|
|
GATE CLOSED indicator goes out, STOP indicator and buzzer come on while baling.
|
Gate latch not adjusted properly.
|
Adjust gate latch stop. (See procedure in Service-Baler section.)
|
|
|
Gate latch switches not adjusted properly.
|
Adjust gate latch switches. (See procedure in Service-Baler section.)
|
|
|
Tractor selector control valve (SCV) leaking oil to gate hydraulic cylinder.
|
Repair tractor selector control valve (SCV). (See your John Deere dealer.)
|
|
|
Gate latch hooks yielded.
|
Replace hooks and adjust gate latch. (See ADJUSTING GATE LATCH STOP in Service-Baler section.)
|
|
|
Air in hydraulic system.
|
Open and close gate several times to remove air.
|
|
|
Internal leak in gate hydraulic cylinder.
|
Repair or replace cylinder. (See your John Deere dealer.)
|
|
|
Hydraulic cylinder not completely retracted when gate is closed.
|
Hold tractor SCV lever 2-3 seconds after GATE CLOSED indicator is displayed.
|
| Symptom |
Problem |
Solution |
|
STOP indicator and buzzer come on when gate is closed.
|
Gate is not latched on one side.
|
Hold tractor SCV lever 2-3 seconds after GATE CLOSED indicator is displayed to make sure both sides are latched.
Repair or adjust latch stop. (See ADJUSTING GATE LATCH STOP in Service-Baler section.)
|
|
|
Gate latch switches not adjusted properly.
|
Adjust gate latch switches. (See procedure in Service-Baler section.)
|
|
|
Defective gate latch switch(es).
|
Check gate latch switches. (See TESTING GATE LATCH AND OVERSIZE BALE SWITCHES in Service-Baler section.) Replace if necessary. (See your John Deere dealer.)
|
|
|
Poor connections or broken wires to gate latch switches.
|
Test wires for continuity. Repair as necessary.
|
|
|
Oversize bale switch out of adjustment.
|
Adjust oversize bale switch. (See procedure in Service-Baler section.)
|
|
|
Shorted wires to oversize bale switch.
|
Test wire shorts. Repair as necessary.
|
| Symptom |
Problem |
Solution |
|
GATE CLOSED indicator is displayed, but gate is open or not latched.
|
Gate latch switches not adjusted properly.
|
Adjust gate latch switches. (See procedure in Service-Baler section.)
|
|
|
Defective gate latch switch(es).
|
Check gate latch switches. (See TESTING GATE LATCH AND OVERSIZE BALE SWITCHES in Service-Baler section.) Replace if necessary. (See your John Deere dealer.)
|
|
|
Crop buildup in latch area restricting hook engagement.
|
Remove buildup.
|
|
|
Shorted wires to gate latch switches.
|
Test wires for shorts. Repair as necessary.
|
|
One or both bar graphs on LCD display do not correspond to shape of bale being formed.
|
Operator not interpreting signal properly.
|
Review INTERPRETING BALE SHAPE INDICATORS in Operating the Baler section.
|
|
|
Bale shape sensors not adjusted properly.
|
Adjust bale shape sensors. (See procedure in Service-Baler section.)
|
|
|
Defective bale shape sensor(s).
|
Replace bale shape sensor(s). (See procedure in Service-Baler section.)
|
|
|
Broken wire(s) between monitor-controller and bale shape sensor(s) or poor connection at harness connectors.
|
Check continuity. Repair wires or connections as necessary.
|
|
|
Faulty display.
|
Test display. (See TESTING LIGHTED CRYSTAL DISPLAY (LCD) in Service-Baler section.)
|
|
Low voltage light comes on.
|
Low voltage to monitor-controller under load.
|
Check voltage. (See CHECKING TRACTOR VOLTAGE in Service-Baler section.)
|
| Symptom |
Problem |
Solution |
|
Bale counter does not count bales.
|
For the monitor-controller to count a bale, an automatic wrap cycle must be followed by a gate opening cycle.
|
Check that both gate latch switches are functioning properly. (See TEST GATE LATCH SWITCHES in Service-Baler section.)
|
|
|
Tension arm twisted from baling with gate lock lever in LOCKED position.
|
Replace tension arm. (See your John Deere Dealer.) (See CHECKING GATE LOCK VALVE INTERLOCK LEVER ADJUSTMENT in Preparing Baler section.)
|
|
|
Tension are must go low enough to trigger next automatic wrap cycle.
|
Check that belts are correct length. Adjust or replace baler size sensor.
|
|
Monitor-controller functions do not display.
|
Monitor-controller was hooked up with reverse polarity.
|
Check polarity of 12 volt power supply.
|
|
|
Intermittent voltage loss due to loose connectors.
|
Disconnect and inspect connectors for bent or pushed back terminals.
|
|
|
Intermittent connection in wiring harness due to broken or frayed wire.
|
Inspect wiring harness and repair or replace.
|
|
STOP indicator is displayed on monitor-controller when activated (E201).
|
Twine disconnected.
|
Check actuator connectors.
|
|
|
Wiring is loose or cut.
|
Check wiring harness connector for breaks.
|
|
Twine Wrap System:
EXTEND/RETRACT and WRAP switches will not move twine actuator. STOP flashes.
|
Wiring has a break in it.
|
Check wiring harness for breaks and check connectors for pushed back pins.
|
|
Twine arm actuator does not come all the way home. Twine does not cut off.
|
Low voltage to the monitor-controller under load.
|
See your John Deere dealer.
|
| Symptom |
Problem |
Solution |
|
Twine arm actuator does not function. Stop indicator displays.
|
Twine arm actuator failed (E202).
|
Replace actuator. (See your John Deere dealer.)
Inspect wiring harness and repair or replace.
|
|
|
Twine arm wedged against front side of knife.
|
Use monitor-controller RETRACT key to retract twine arm. Clean and lubricate knife pivot.
|
|
Twine actuator does not complete its travel. STOP indicator displays and alarm sounds.
|
Twine arm travel restricted by foreign object or hay buildup.
|
Inspect and remove blockage.
|
|
Automatic twine cycle does not function. STOP indicator displays and alarm sounds.
|
Defective gate latch switch(es).
|
Replace switch(es). See your John Deere dealer.
|
|
|
Incorrect gate latch switch adjustment.
|
Adjust gate latch switches. (See procedure in Service-Baler section.)
|
|
|
Gate not closed completely and does not activate one gate switch.
|
Remove hay buildup from gate area.
Operate baler at tractor rated PTO speed when closing the gate.
|
|
|
Released selective control valve too soon after closing gate.
|
Continue to hold selective control valve 2 seconds after gate closes.
|
|
|
Gate twisted and does not close completely.
|
See your John Deere dealer.
|
|
|
Manual BYPASS wiring harness connected.
|
Return twine actuator connector to NORMAL OPERATION connector. (See USING BYPASS SWITCH [TWINE WRAP ONLY] in Operating the Baler section.)
|
| Symptom |
Problem |
Solution |
|
Twine arm actuator stops at full extension and will not retract.
|
Monitor-controller set for incorrect baler model.
|
Change monitor-controller setting. (See CHANGING BALER MODEL PROGRAM in Operating the Baler section.)
|
|
|
|
Inspect wiring harness. Repair or replace.
|
|
Twine spacing to edge of bale is greater than monitor-controller setting.
|
Incorrect mechanical twine guide setting.
|
Adjust mechanical twine guide. (See SETTING TWINE SPACING and SETTING TWINE END WRAP DISTANCE in Operating the Baler section.)
|
|
Number of end wraps is different than monitor-controller setting.
|
Incorrect bale diameter sensor adjustment.
|
Adjust bale diameter sensor. (See procedure in Service-Baler section.)
|
|
|
Not operating at tractor rated PTO speed. (without slip clutch alert)
|
Operate at rated PTO speed or at a consistent speed. A constant speed less than rated PTO speed will require a different monitor-controller setting.
|
| Symptom |
Problem |
Solution |
|
Erratic twine spacing.
|
Incorrect monitor-controller settings.
|
Reset to factory initial settings and check baler model number. (See RESETTING BaleTrak
Pro TO INITIAL FACTORY SETTINGS and CHANGE BALER MODEL PROGRAM in Operating the Baler section.)
|
|
|
Not operating at tractor rated PTO speed. (without slip clutch alert)
|
Operate at rated PTO speed or at a consistent speed. A constant speed less than rated PTO speed will require a different monitor-controller setting.
|
|
|
Distance between twine arms incorrect for monitor-controller setting.
|
Set twine arm spacing for monitor-controller setting. (See SETTING TWINE SPACING in Operating the Baler section.)
Inspect wiring harness. Repair or replace.
|
|
Twine wrapping settings not consistent with different bale sizes.
|
Not operating at tractor rated PTO speed. (without slip clutch alert)
|
Operate at rated PTO speed or a consistent speed. A constant speed less than rated PTO speed will require a different monitor-controller setting.
|
|
|
Incorrect bale diameter sensor adjustment.
|
Adjust sensor. (See ADJUSTING BALE DIAMETER SENSOR in Service-Baler section.)
|
|
Net Wrap System: (E211)
Net actuator will not function during auto cycle. STOP flashes.
|
Wiring has a break in it.
|
Check wiring harness for breaks and check connectors for pushed back pins.
|
|
Net actuator does not move when EXTEND/RETRACT switches are pressed in net mode.
|
The EXTEND/RETRACT switches are not intended to control net actuator in net mode.
|
See TESTING TWINE WRAP ACTUATOR CURRENT (CHANNEL 18) in Service section.
|
|
Net actuator does not come all the way home. Net does not cut off.
|
Low voltage to the monitor-controller under load.
|
See Testing Tractor Convenience Outlet Voltage (Channel 19) in Service Baler section
|
| Symptom |
Problem |
Solution |
|
Net wrap indicator and alarm activates.
|
Knife did not cut the net wrap material. (E401)
|
Adjust knife and brake. (See CHECKING NET WRAP KNIFE ARM BRAKE in Service-Net Wrap section.)
Sharpen knife. (See SHARPENING NET WRAP CUTOFF KNIFE in Service-Net Wrap section.)
Adjust knife to rubber flap. (See ADJUSTING NET WRAP KNIFE ARM STOP in Service-Net Wrap section.)
|
|
|
Incorrect net wrap switch adjustment. (E401)
|
Adjust net wrap switch. (See procedure in Service-Net Wrap section.)
|
|
|
Net wrap switch actuator lever not free to rotate.
|
Check actuator lever for obstruction or corrosion in hinged area.
|
|
Net wrapping settings not consistent with different bale sizes.
|
Not operating at tractor rated PTO speed. (without slip clutch alert)
|
Operate at rated PTO speed or a consistent speed. A constant speed less than rated PTO speed will require a different monitor-controller setting.
|
|
|
Incorrect bale diameter sensor adjustment.
|
Adjust sensor. (See ADJUSTING BALE DIAMETER SENSOR in Service-Baler section.)
|