First 50 Hours
Gear Case
NOTE: Driveline removed for illustration purposes.

E57911-UN-25AUG09
Removing Drain Plug
Drain and refill gear case after the first 50 hours.
IMPORTANT: Do not over fill gear case as this will result in
overheating and oil leakage.
Check level of lubricant with dipstick. Lubricant must fall
between grooves on dipstick.
Refill as necessary using SAE 85-140 API GL-5 gear lubricant.
Drain and refill gear case once each season.
| Item | Measurement | Specification |
|
Gear Case | Capacity | 1.2 L (1.25 qt.) |
Tighten dipstick to specification.
| Item | Measurement | Specification |
|
Dipstick | Torque | 29 ± 3 N·m (21 ± 2 lb.-ft.) |
|
|