NOTE: Microswitch position and operation can be checked by using
the monitor-controller diagnostic channels.
Start tractor engine.
-

E52528-UN-26JUN03
A - COUNTER Key
B - PLUS Key
Press and hold COUNTER key (A) while turning monitor-controller
ON.
-
Continue to hold COUNTER key and press PLUS key (B) until digital
display shows desired channel.
-
Release key and view reading (gate closed).
-
NOTE: Tension arm must be fully raised for oversize bale switch
to be closed.
Open gate and view reading or listen for tone.
-
If readings are not as shown, adjust switch position and test
again. (See ADJUST GATE CLOSE SWITCH and ADJUST OVERSIZE BALE SWITCH
in this section.)
|
Diagnostic Channel
|
Function
|
Gate Closed Reading
|
Gate Open Reading
|
|
013
|
Oversize Bale Switch
|
013 (Switch Released)
|
00 (Zero) (Switch Depressed) (Tone)
|
|
014
|
Gate Switch
|
00 (Zero) (Switch Depressed)
|
014 (Switch Released) (Tone)
|
-
If switch adjustment does not produce normal readings:
-
Turn monitor-controller OFF. Turn tractor key to OFF position.
Remove key.
-
Check for correct wire connections. (See WIRE HARNESS DIAGRAM—BALER
in this section.)
-
Check wire harness for cuts and breaks.
-
Check harness connectors for damaged (pushed back) terminals.
-
Replace switch if necessary. (See your John Deere dealer.)