Test Gate Close and Oversize Bale Switches—Monitor-Controller Assisted Test (Channels 013 and 014)

  1. NOTE: Microswitch position and operation can be checked by using the monitor-controller diagnostic channels.

    Start tractor engine.

  2. E52528
    E52528-UN-26JUN03

    A - COUNTER Key

    B - PLUS Key

    Press and hold COUNTER key (A) while turning monitor-controller ON.



  3. Continue to hold COUNTER key and press PLUS key (B) until digital display shows desired channel.

  4. Release key and view reading (gate closed).

  5. NOTE: Tension arm must be fully raised for oversize bale switch to be closed.

    Open gate and view reading or listen for tone.

  6. If readings are not as shown, adjust switch position and test again. (See ADJUST GATE CLOSE SWITCH and ADJUST OVERSIZE BALE SWITCH in this section.)

    Diagnostic Channel

    Function

    Gate Closed Reading

    Gate Open Reading

    013

    Oversize Bale Switch

    013 (Switch Released)

    00 (Zero) (Switch Depressed) (Tone)

    014

    Gate Switch

    00 (Zero) (Switch Depressed)

    014 (Switch Released) (Tone)

  7. If switch adjustment does not produce normal readings:

    1. Turn monitor-controller OFF. Turn tractor key to OFF position. Remove key.

    2. Check for correct wire connections. (See WIRE HARNESS DIAGRAM—BALER in this section.)

    3. Check wire harness for cuts and breaks.

    4. Check harness connectors for damaged (pushed back) terminals.

    5. Replace switch if necessary. (See your John Deere dealer.)

PP98408,0000FC4-19-20130207