IMPORTANT: Current overload protection to twine actuator is
bypassed when using channel 018. Extended use of channel 018 can cause
actuator damage.
NOTE: Channel 018 allows operator use of EXTEND and RETRACT
keys to position actuator for service.
-
IMPORTANT: Remove roll of net wrap material from baler if testing
net actuator voltage. Otherwise, if PTO is engaged with net actuator
extended, net will feed into empty baler and can cause damage to pickup
or rotary feed system.
If testing net and wrap actuator current, remove roll of net
wrap material from baler.
-
Turn tractor key to ON position. Do not start tractor engine.
-
Press and hold COUNTER key (A) while turning monitor-controller
ON.
-
Continue to hold COUNTER key and press PLUS key until CH018 appears in digital display.
-
Release COUNTER key; digital display will change to show actuator
static current flow reading of 0 to 1.
-
Use EXTEND and RETRACT keys (B) and (C) to operate actuator
in both directions. Display must show a current flow reading between 1 and 8 while actuator
motor is operating during mid stroke (no load).
-
Below normal readings indicate low tractor voltage, or poor
or corroded harness connections
-
Above normal readings indicate binding linkage or partially
shorted motor windings
-
Current spike reading indicates mechanical obstruction to linkage
-
Continue to operate actuator to fully retracted position. Display
must show stall (load) current reading between 22 and 30.
-
Below normal reading indicates bad or corroded harness connections
-
Above normal reading indicates partially shorted motor windings
or actuator binding
-
Press RETRACT key to move actuator to home position.
-
Turn monitor-controller OFF. Turn tractor key to OFF position.
Remove key.