BaleTrak™ Pro Monitor-Controller Channels

NOTE: Channel listings and page numbers can be found under Operating the Baler or Service—Baler in the Contents or under section C in the Index.

NOTE: Monitor will power off after 30 minutes of inactivity.

 

CUSTOMER and SETUP CHANNELS

 

Channel Number

Contents

Remarks

001

Reset All Settings to Factory Initial Settings

See factory initial settings

002

Dry Straw Twine Wrap Program

Plus key turns ON, minus turns OFF

003

Re-extension Twine Tying Program

Plus key turns on and increases, minus turns off and decreases (OFF, 8.0, 16.0, 24.0)

004

Cinch Wrap Twine Tying Program

Plus key turns ON, minus turns OFF

005

Calibration of Bale Size Diameter Sensor

At value 208

006

Net Wrap Delay

Default value will be 2 (0-8) seconds

007

Calibration of Right Belt Tension Sensor

At value 176

008

Measurement Units

Will display Sl for metric and En for English

009

Calibration of Left Belt Tension Sensor

At value 176

010

Offset of Near Full Alarm

Initial setting is 4.5 (0.5-10.0) inches

011

Bale Shape Sensitivity

Initial setting is 3 (1-5)

012

Test of Net Switch

Released=12 & tone, depressed=00

013

Test of Oversize Switch

Released=12, depressed=00 & tone

014

Test of Right Gate Latch Switch

Released=12 & tone, depressed=00

015

Test of Left Gate Latch Switch

Released=12 & tone, depressed=00

016

PTO RPM Sensor Output

Read the speed

017

Pickup RPM Sensor Output

Read the speed

018

Test of Current in Actuators

Read the current

019

Test of System Voltage

Read the voltage

020

Test of LCD Screen

Display all segments

029

Twine Arm Calibration Value

 

033

Delay of Twine Eject

Default 0 (0—10) Seconds

034

Net cutoff for B-Wrap

See Adjust Cut Position, in this section for initial setting

035

Bale orientation for B-Wrap

See Adjust Bale Orientation, in this section for initial setting

201

Baler Model

4xx to 5xx

202

Twine

0= OFF, 1= ON

203

Net

0= OFF, 1= ON

204

PTO Sensor

0= OFF, 540 or 1000= ON

205

Pickup Sensor

0= OFF, 310= ON

206

PTO Sensor Calibration

24= Number of Fins on PTO Clutch

207

Pickup Sensor Calibration

10= Number of Teeth on Wheel

208

Variable Core

0= OFF, 1= ON

OUO6064,00015D7-19-20151009