Error Code
|
Description
|
Solution
|
|
E0 01
|
Erratic supply voltage when actuator operating
|
Check Battery and Alternator
Check wires and connections
see Channel 019 in Service section
|
|
E0 02
|
Low Voltage
|
Check Alternator
Check that wires and connections perform voltage test, see Testing
Tractor Outlet Voltage, Channel 019, in Service Section
|
|
E0 03
|
High Voltage
|
Check alternator
See Channel 019 in Service section
|
|
E1 02
|
Bale size sensor disconnected or shorted to ground
|
Check wires and connectors
Check sensor
|
|
E1 03
|
Bale size sensor shorted to power
|
Check wires and connectors
Check sensor
|
|
E1 04
|
Bale size sensor below working range
|
Check sensor adjustment, see Channel 005 in Service section
|
|
E1 05
|
Bale size sensor above working range
|
Check sensor adjustment, see Channel 005 in Service section
|
|
E1 12
|
Right bale shape sensor shorted to ground
|
Check wire and connectors
Check sensor
|
|
E1 13
|
Right bale shape sensor shorted to power
|
Check wire and connectors
Check sensor
|
|
E1 14
|
Right bale shape sensor below working range
|
Check sensor adjustment, see Channel 007 in Service section
|
|
E1 15
|
Right bale shape sensor above working range
|
Check sensor adjustment, see Channel 007 in Service section
|
|
E1 22
|
Left bale shape sensor shorted to ground
|
Check wire and connectors
Check sensor
|
|
E1 23
|
Left bale shape sensor shorted to power
|
Check wire and connectors
Check sensor
|
|
E1 24
|
Left bale shape sensor below working range
|
Check sensor adjustment, see Channel 009 in Service section
|
|
E1 25
|
Left bale shape sensor above working range
|
Check sensor adjustment, see Channel 007 in Service section
|
|
E2 01
|
Twine actuator disconnected
|
Check wires and connectors
|
|
E2 02
|
Twine actuator faulty
|
Check that twine actuator using extend or retract switches
Check twine actuator using by-pass switch
|
|
E2 03
|
Timeout error during twine wrapping cycle
|
Check for obstruction or binding
|
|
E2 04
|
Twine actuator harness shorted to battery
|
Check wires and connectors
Check twine actuator
|
|
E2 05
|
Twine actuator harness shorted to ground
|
Check wires and connectors
Check sensor
|
|
E2 11
|
Net actuator disconnected
|
Check wires and connectors
|
|
E2 12
|
Net actuator faulty
|
Using channel 019, check that net actuator using extend or retract
switches
|
|
E2 13
|
Timeout error during net wrapping cycle
|
Check for obstruction or binding
|
|
E2 14
|
Net actuator harness shorted to battery
|
Check wires and connectors
Check net actuator
|
|
E2 15
|
Net actuator harness shorted to ground
|
Check wires and connectors
Check net actuator
|
|
E2 17
|
B-Wrap sensor did not detect metal tag
|
Check B-Wrap roll velcro fasteners
Check B-Wrap sensor harness and adjustment
|
|
E2 21
|
Variable core valve disconnected
|
Check wires and connectors
Check variable core valve solenoid
|
|
E2 22
|
Variable core valve shorted to power
|
Check wires and connectors
Check variable core valve solenoid
|
|
E2 23
|
Variable core valve shorted to ground
|
Check wires and connectors
Check variable core valve solenoid
|
|
E3 01
|
Open circuit PTO RPM sensor
|
Check wires, connectors, and sensor for damage. Check
sensor readout on channel 016, See Wrap cycle without PTO engaged.
|
|
E3 02
|
PTO sensor less than minimum speed
|
Check sensor adjustment and sensor readout, See sensor readout
on channel 017 for approximately 310 rpm. Speed must not vary more
than 5 rpm.
|
|
E3 03
|
PTO sensor exceeds maximum speed
|
Check sensor adjustment and sensor readout, See sensor readout
on channel 017 for approximately 310 rpm. Speed must not vary more
than 5 rpm.
|
|
E4 01
|
Net did not wrap bale
|
See net section of troubleshooting
|
|
E4 02
|
Net did not cut
|
See net section of troubleshooting
|
|
E4 11
|
Right gate switch always open
|
Check right gate switch adjustment and function. See right gate
switch adjustment and testing, Channel 014 in Service section
|
|
E4 12
|
Right gate switch always closed
|
Check right gate switch adjustment and function. See right gate
switch adjustment and testing, Channel 014 in Service section
|
|
E4 21
|
Left gate switch always open
|
Check left gate switch adjustment and function. See right gate
switch adjustment and testing, Channel 015 in Service section
|
|
E4 22
|
Left gate switch always closed
|
Check left gate switch adjustment and function. See right gate
switch adjustment and testing, Channel 015 in Service section
|
|
E4 31
|
Oversize switch always open
|
Check oversize switch adjustment and function. See oversize
bale switch adjustment and testing, Channel 013 in Service section
|
|
E5 01
|
Open circuit, negative sensor circuit
|
Check sensor wires, connectors, and sensors
|
|
E5 02
|
Grounded circuit, negative sensor circuit
|
Check sensor wires, connectors, and sensors
|
|
E5 03
|
Shorted circuit, negative sensor circuit
|
Check sensor wires, connectors, and sensors
|
|
E5 11
|
Open circuit, positive sensor circuit
|
Check sensor wires, connectors, and sensors
|
|
E5 12
|
Grounded circuit, positive sensor circuit
|
Check sensor wires, connectors, and sensors
|
|
E5 13
|
Shorted circuit, positive sensor circuit
|
Check sensor wires, connectors, and sensors
|
|
LOnEt
|
Roll of B-Wrap material is empty
|
Load new roll of wrap material
|