BaleTrak™ Pro Monitor-Controller Setup Values and Initial Settings

BALE DIAMETER

Readout Display Range..............

57—191 cm (22.5—75 in.)

Diameter Adjustment Range..............

81—183 cm (32—72 in.)

Diameter Initial Setting1..............

168 cm (66 in.)

Near Full Size Range..............

1—27 cm (0.5—10.0 in.)

Near Full Size Initial Setting1..............

11 cm (4.5 in.)

Bale Shape Sensitivity Range..............

1 (slowest) — 5 (fastest)

Bale Shape Sensitivity Initial Setting1..............

3 (medium)

TWINE WRAP

Spacing Range..............

2—26 cm (1—10 in.)

Spacing Initial Setting1..............

10 cm (4 in.)

Number of End Wraps Range

Left-Hand End..............

0—5 Wraps

Right-hand End..............

0.5—5.0 Wraps

Number of End Wraps Initial Setting1..............

2 Wraps

Left-Hand, Right-Hand End Wrap Distance Range..............

8—26 cm (3—10 in.)

End Wrap Distance Initial Setting (Right and Left-Hand)1..............

10 cm (4 in.)

Re-Extension Wrap Distance Range..............

OFF1, 20, 40, 60 cm (8, 16, 24 in.)

Cinch Wrap Initial Setting (From Left-Hand End)..............

OFF1, 25 cm (10 in.)

Dry Straw..............

OFF1, ON

Delay of Twine Eject..............

0—10 Seconds

Delay of Twine Eject, Initial Setting..............

0 Seconds

NET WRAP

Number of Wraps..............

1.5—10.0

Number of Wraps Initial Setting1..............

2

Time Delay Range (From Full-Size Bale Alert to Start of Net Wrap Cycle)..............

0—8 Seconds

Time Delay Initial Setting1..............

2 Seconds

VARIABLE CORE DIAMETER

Diameter Adjustment Range..............

61—173 cm (24—68 in.)2

Diameter Initial Setting1..............

91 cm (36 in.)

1 Settings revert to these values when monitor-controller is reset. (See BaleTrak™ Pro MONITOR-CONTROLLER—RESET TO INITIAL SETTINGS [CH 001] in this section.)
2 10 cm (4 in.) below size setting.

PP98408,000101B-19-20130222