Check Microswitches
-
NOTE: Label wires before disconnecting from switch to ensure
proper connection to switch terminals. Only terminals
(A) and (B) are used.

E38432-UN-21FEB95
A - Common Terminal
B - Normally Open Terminal
C - Normally Closed Terminal
Disconnect all wires from switch.
-
Attach multimeter leads to common (A) and normally open (B)
terminals.
-
When switch lever is released, there must be no continuity through
the switch.
-
When lever is depressed (click is heard), there must be continuity
through the switch.
-
Move lead from normally open (B) to normally closed (C) terminal.
-
When switch lever is released, there must be continuity through
the switch.
-
When lever is depressed (click is heard), there must be no continuity
through the switch.
-
If continuity test results are not as described, replace switch.
|
|
PP98408,00010E5-19-20130211
|
|