Supplemental Coolant Additives
IMPORTANT: This machine is NOT filled
with John Deere COOL-GARD products from the factory. Do not use John Deere Coolant Conditioner
until after initial flush and refill with John Deere coolant.
Some coolant additives will gradually deplete during engine
operation. For nitrite-containing coolants, replenish coolant additives
between drain intervals by adding a supplemental coolant additive
as determined necessary by coolant testing.
John Deere Liquid Coolant Conditioner is recommended as a supplemental
coolant additive for nitrite-containing coolants.
John Deere Liquid Coolant Conditioner is not designed for use
with John Deere COOL-GARD II Premix, COOL-GARD II PG Premix, or COOL-GARD II Concentrate.
IMPORTANT: Do not add a supplemental coolant additive when the
cooling system is drained and refilled with any of the following:
-
John Deere COOL-GARD II
-
John Deere COOL-GARD II PG
If other coolants are used, consult the coolant supplier and
follow the manufacturer's recommendation for use of supplemental coolant
additives.
The use of non-recommended supplemental coolant additives may
result in additive drop-out and gelation of the coolant.
Add the manufacturer's recommended concentration of supplemental
coolant additive. DO NOT add more than the recommended amount.
|
COOL-GARD is a trademark of Deere & Company
|
OUO6043,0000207-19-20130212
|
|