Check Engine Coolant
Check the engine coolant level at the surge tank every 10 hours
of operation.
CAUTION:

TS281-UN-23AUG88

E65100-UN-18JUN12
C - Maximum Fill Line
D - Minimum Fill Line
Explosive release of coolant from pressurized cooling system
can cause serious burns.Remove surge tank fill cap only
when cool enough to touch with bare hands and with engine stopped.
Do not remove fill cap until all system pressure is relieved.
Relieve pressure by slowly loosening cap to relieve pressure before
removing completely.
IMPORTANT: In case of excessive coolant loss, never pour cold
water into a hot engine, as it might crack cylinder block or head. Never operate, even for a few minutes, engine without coolant.
Never fill radiator when engine is overheated, unless engine
is idling slowly. Pour coolant in slowly.
Never use high silicate automotive coolant.
NOTE: Fill system with specified coolant that contains coolant
conditioner. (See DIESEL ENGINE COOLANT in Fuel, Coolant, and Lubricants
section).
-
Check coolant level in surge tank. If coolant is below minimum
fill line (D), add coolant.
-
Add coolant through filler cap on tank to maximum fill line
(C).
-
NOTE: Cooling system capacity is approximately 11.9 (12.6. gal).
Start and run engine for several minutes with fill cap off.
-
Stop engine, remove key. Let system cool and check level in
coolant tank.
-
Add coolant as needed to tank. Install fill cap.
|
|
RC48509,000057E-19-20120814
|
|