CDM / WCM Fault Codes


W110

E 1

     

E 2

 

RTC NOT ALLOWED

Return To Cut activated with the header off.

E 3

     

E 4

     

E 5

     

E 6

 

TEMP GAUGE SHORT

Wiring / connection problem.

E 7

 

SPEED STICK SHORT

Wiring / connection problem.

E 8

 

HEADER ENABLE SHORT

Wiring / connection problem.

E 9

     

E 10

 

CDM INTERNAL ERROR

Internal hardware or software problem.

E 11

 

CDM POWER UP

CDM Module did not power up correctly.

E 12

     

E 13

 

FUEL SOLENOID

WCM Fuel solenoid output fault detected.

Error codes E14 to E23 not allocated

 

E 24

E124

DECK SHFT RIGHT P95

Right Deck Shift solenoid P95 on header fault detected - short circuit/open circuit

E 25

E125

DECK SHFT LEFT P96

Left Deck Shift solenoid P96 on header fault detected - short circuit/open circuit

E 26

E126

   

E 27

E127

   

E 28

E128

TILT P2A

Header Tilt solenoid P2A (V2A) fault detected - short circuit/open circuit

E 29

E129

TILT P4C

Header Tilt solenoid P4C (V4C) fault detected - short circuit/open circuit

E30

E130

4 WAY VALVE P5A

4 Way valve solenoid P5A (V5A) fault detected - short circuit / open circuit

E 31

E131

BYPASS VALVE P1

Bypass valve solenoid P1 (V1) fault detected - short circuit / open circuit

E 32

E132

HEADER UP/DOWN P4A

Header up / down solenoid P4A (V4A) fault detected - short circuit / open circuit

E 33

E133

SCREEN CLEANERS

Screen cleaner output fault detected - short circuit / open circuit

E 34

E134

RIGHT STOP LAMP

Right stop lamp output fault detected - short circuit / open circuit

E 35

E135

LEFT STOP LAMP

Left stop lamp output fault detected - short circuit / open circuit

E 36

E136

RIGHT TURN LAMP

Right turn lamp output fault detected - short circuit / open circuit

E 37

E137

LEFT TURN LAMP

Left turn lamp output fault detected - short circuit / open circuit

E 38

     

E 39

     

E 40

E140

HIGH RANGE P5B

High range solenoid P5B (V5B) fault detected - short circuit / open circuit

E 41

     

E 42

E142

REEL P4D

Reel fore / aft solenoid P4D (V4D) fault detected - short circuit / open circuit

E 43

E143

REEL UP / DOWN P4B

Reel up / down solenoid P4B (V4B) fault detected - short circuit / open circuit

E 44

     

E 45

     

E 46

 

SENSOR VOLTS HIGH

CDM’s 9V Sensor voltage output high. (wire 5019)

E 47

 

SENSOR VOLTS LOW

CDM’s 9V Sensor voltage output low. (wire 5019)

E 48

     

E 49

     

E 50

 

BATT + OUT OF RANGE

System voltage above 15.5 VDC.

E 51

E151

DISK DRIVE PWM V8

Disk header drive solenoid V8 fault detected - short circuit / open circuit

ERROR codes E52 thru E64 not allocated

 

E 65

 

KNIFE SPD OVERLOAD

Low knife speed detected. (less than programmed overload speed in CDM)

E 66

 

##.# LOW VOLTS

Low system voltage <11.5 VDC

E 67

 

TRANS OIL PRESSURE

Supercharge pressure low (switch 208 hydraulic schematic))

E 68

 

TRANS OIL TEMP

Transmission oil temperature >221 degrees F (110 degrees C).

E 69

     

E 70

     

E 71

 

LOW HYDRAULIC OIL

Low hydraulic oil level sensor tripped. (switch 225 hydraulic schematic))

E 72

 

##.# HIGH VOLTS

System voltage above 15.5 VDC.

Error codes E73 thru E100 not allocated

E101

 

SPI ERROR

J1939 Can error

E102

 

CAN ERROR

J1939 Can error

E103

 

EEPROM READ ERROR

Internal error

E104

 

EEPROM WRITE ERROR

Internal error

E105

 

TEMP SENSOR ERROR

Internal temperature sensor error

Miscellaneous Information / Error Codes

ENGINE OIL PRESSURE

Engine oil pressure warning

ENGINE TEMPERATURE

Engine coolant temperature warning

CANBUSS ERROR

J1939 Can Error

KNIFE SPD OVERLOAD

Low knife speed detected (less than programmed overload speed) Logged as E65

NO OPERATOR

Operator not detected in seat (3 second delay before message)

DISENGAGE HEADER

Header engage switch on when ignition turned on

x x x x S x x F x x C

Engine error code configuration (Canbus) - see engine error codes.

CENTER STEERING

GSL or Pintal switches not closed with the key on / engine off

NOT IN PARK

Pintal switches not closed with the key on / engine off

BRAKE ON

Engine running GSL out of PARK brake is still engaged.

PLACE GSL INTO “N”

GSL or Pintal switches not closed with the key on / engine off.

BRAKE SW FAILURE

Ignition on / engine not running - relay closed, brake solenoid on.

BRAKE OFF

Engine running - brake solenoid not activated.

In the case of dual codes being shown for an item (primarily the solenoid valves) the first code indicates a SHORT CIRCUIT condition, while the second code indicates an OPEN CIRCUIT condition. E41 would be a SHORT in the feel fore / aft solenoid V2C while E141 would indicate an OPEN circuit.


W150

E 1

 

RANGE NOT ALLOWED

HIGH range activated while in Cab forward

E 2

 

RTC NOT ALLOWED

Return To Cut activated with the header off.

E 3

 

SIGNALS NOT ALLOWED

Turn Signals activated while in Cab forward

E 4

 

HDR DRV NOT ALLOWED

Header engage switch activated while Engine forward

E 5

 

RTC NOT AVAILABLE

Return To Cut activated while in Engine forward

E 6

 

TEMP GAUGE SHORT

Wiring / connection problem

E 7

 

SPEED STICK SHORT

Wiring / connection problem

E 8

 

HEADER ENABLE SHORT

Wiring / connection problem

E 9

 

WCM ENABLE SHORT

Wiring / connection problem

E 10

 

CDM INTERNAL ERROR

Internal hardware or software problem

E 11

 

CDM POWER UP

CDM Module did not power up correctly

E 12

 

WCM POWER UP

WCM Module did not power up correctly

E 13

 

FUEL SOLENOID

WCM Fuel solenoid output fault detected

E 14

 

DWA DRIVE PWM V13

DWA Drive - PWM solenoid drive fault detected - short circuit / open circuit

E 15

E115

KNIFE DRIVE PWM V8

Knife drive - PWM solenoid drive fault detected - short circuit / open circuit

E 16

E116

DRAPER DRV PWM V9A

Draper Drive - PWM solenoid drive fault detected - short circuit / open circuit

E 17

E117

REEL DRIVE PW

Reel Drive - PWM solenoid drive fault detected - short circuit / open circuit

E 18

     

E 19

E119

LOAD SENSE V16

Disc Block valve 16 - solenoid drive fault detected - short circuit / open circuit

E 20

     

E 21

E121

REVERSER V11C

Reverser - Solenoid V11 fault detected - short circuit / open circuit

E 22

     

E 23

E123

REVERSER V11A / B / 12

Reverser - Solenoid V11A, 11B or 12 fault detected - short circuit / open circuit

E 24

E124

DECK SHFT RIGHT V14

Right Deck Shift solenoid V14 fault detected - short circuit / open circuit

E 25

E125

DECK SHFT LEFT V15

Left Deck Shift solenoid V15 fault detected - short circuit / open circuit

E 26

E126

DWA UP V2 C2

DWA Raise solenoid V2C2 fault detected - short circuit / open circuit

E 27

E127

DWA DOWN V4C2

DWA Lower solenoid V4C2 fault detected - short circuit / open circuit

E 28

E128

TILT RETRACT V2B

Tilt Retract solenoid V2B fault detected - short circuit / open circuit

E 29

E129

TILT EXTEND V2A

Tilt Extend solenoid V4C fault detected - short circuit / open circuit

E30

E130

4 WAY VALVE V6

4 Way valve solenoid V5 fault detected - short circuit / open circuit

E 31

E131

BYPASS VALVE V1

Bypass valve solenoid V1 fault detected - short circuit / open circuit

E 32

E132

HEADER UP/DOWN V4A

Header up / down solenoid V4A fault detected - short circuit / open circuit

E 33

E133

SCREEN CLEANERS

Screen cleaner output fault detected - short circuit / open circuit

E 34

E134

RIGHT STOP LAMP

Right stop lamp output fault detected - short circuit / open circuit

E 35

E135

LEFT STOP LAMP

Left stop lamp output fault detected - short circuit / open circuit

E 36

E136

RIGHT TURN LAMP

Right turn lamp output fault detected - short circuit / open circuit

E 37

E137

LEFT TURN LAMP

Left turn lamp output fault detected - short circuit / open circuit

E 38

E138

MAIN DRIVE V10

Main header drive solenoid V10 fault detected - short circuit / open circuit

E 39

E139

   

E 40

E140

HIGH RANGE V5A

High range solenoid V3A fault detected - short circuit / open circuit

E 41

E141

REEL AFT V2B

Reel aft solenoid V2B fault detected - short circuit / open circuit

E 42

E142

REEL FORE V4D

Reel fore solenoid V4D fault detected - short circuit / open circuit

E 43

E143

REEL UP / DOWN V4B

Reel up / down solenoid V4B fault detected - short circuit / open circuit

E 44

E144

   

E 45

E145

   

E 46

 

SENSOR VOLTS HIGH

Sensor voltage output high

E 47

 

SENSOR VOLTS LOW

Sensor voltage output low

E 48

     

E 49

     

E 50

 

BATT + OUT OF RANGE

System voltage above 16.5 VDC

E 51

E151

   

ERROR codes E52 thru E63 not allocated

E 64

     

E 65

     

E 66

 

##.# LOW VOLTS

Low system voltage <11.5 VDC

E 67

 

TRANS OIL PRESSURE

Drive supercharge pressure low (202)

E 68

 

TRANS OIL TEMP

Transmission oil temperature >221 degrees F

E 69

     

E 70

     

E 71

 

LOW HYDRAULIC OIL

Low hydraulic oil level sensor tripped (225)

E 72

 

##.# HIGH VOLTS

System voltage above

Error codes E73 thru E100 not allocated

E101

 

SPI ERROR

J1939 Can error

E102

 

CAN ERROR

J1939 Can error

E103

 

EEPROM READ ERROR

Internal error

E104

 

EEPROM WRITE ERROR

Internal error

E105

 

TEMP SENSOR ERROR

Internal temperature sensor error

Miscellaneous Information / Error Codes

ENGINE OIL PRESSURE

Engine oil pressure warning

ENGINE TEMPERATURE

Engine coolant temperature warning

CANBUSS ERROR

 

KNIFE SPD OVERLOAD

Knife speed is < programmed setpoint while header engaged

NO OPERATOR

Operator not detected in seat (3 second delay before message)

NO HEADER

No header ID detected - not hooked up or wiring error

LOCK SEAT BASE

Seat base not detected in either Cab or Engine forward position

DISENGAGE HEADER

Header engage switch on when ignition turned on

x x x x S x x F x x C

Engine code configuration (Canbus)

CENTER STEERING

GSL or Pintal switches not closed with the key on / engine off

NOT IN PARK

GSL or Pintal switches not closed with the key on / engine off

BRAKE ON

 

PLACE GSL INTO “N”

GSL or Pintal switches not closed with the key on / engine off

BRAKE SW FAILURE

Ignition on / engine not running - brake switch and relay closed

BRAKE OFF

Engine running - brake solenoid not activated

CHECK SEAT SWITCHES

System detects that both seat switches are active

CAB FORWARD SW ON

ENG FORWARD SW ON

If both switches are detected to be activated then the display will alternately flash between these two messages

In the case of dual codes being shown for an item (primarily the solenoid valves) the first code indicates a SHORT CIRCUIT condition, while the second code indicates an OPEN CIRCUIT condition. E41 would be a SHORT in the feel fore / aft solenoid V2C while E141 would indicate an OPEN circuit.

RC48509,00005C5-19-20120906