Test Net Wrap Actuator Current (Channel 018)

Channel 018 allows operator to use the EXTEND and RETRACT keys to position the net actuator for service.

E52520
E52520-UN-26JUN03

BaleTrak™ Pro Monitor

E84427
E84427-UN-06SEP17

BaleTrak™ Plus Monitor

A - COUNTER Key

B - EXTEND Key

C - RETRACT Key

This test is used to determine the working condition of the actuator through its entire range of operation.

  1. Turn the tractor ignition key to the ON position. Do not start the tractor engine.

  2. Remove net wrap material from the baler while performing this test. Otherwise, if the PTO is engaged with the net actuator extended, net feeds into the empty baler and can cause damage to the pickup or rotary feed system.

    Remove the roll of net wrap material from the baler.

  3. With the monitor-controller in the NET mode, press and hold the COUNTER key (A) while turning the monitor-controller ON.

  4. Continue to hold the COUNTER key and press the PLUS key until CH 018 appears in the digital display.

  5. Release COUNTER key; the digital display changes to show the actuator static current flow reading of 0—1.

  6. Use the EXTEND key (B) and the RETRACT key (C) to operate the actuator in both directions. The display must show a current flow reading between 1—8 while the actuator motor is operating during mid stroke (no load).

    • Below normal readings indicate low tractor voltage, or poor or corroded harness connections.
    • Above normal readings indicate binding linkage or partially shorted motor windings.
    • A spike in the current reading indicates a mechanical obstruction to the linkage.

  7. Net wrap actuator is at full stroke position when actuator is fully extended.

    Continue to operate actuator to full stroke position. Display must show a stall (load) current reading between 22—30.

    • Below normal reading indicates bad or corroded harness connections
    • Above normal reading indicates partially shorted motor windings or actuator binding

  8. Press the RETRACT key to move the actuator to the home position.

  9. Turn the monitor-controller OFF. Turn the tractor ignition key to the OFF position and remove the key.

DP99999,0000E15-19-20170906