Turn the tractor ignition key to the ON position. Start the
tractor engine. Using the SCV lever, ensure that the gate is fully
closed.
-

E84666-UN-27SEP17
BaleTrak™ Pro Monitor

E84402-UN-31AUG17
BaleTrak™ Plus Monitor
A - COUNTER Key
B - PLUS Key
Press and hold the COUNTER key (A) while turning the monitor-controller
ON.
-
Continue to hold the COUNTER key and press the PLUS key (B)
until the digital display shows CH014.
-
Release the keys and view the reading on the display. Verify
that the display reads 00.
-
Using the SCV lever, raise the gate to full height.
-
Verify that the display reads 012 and the alarm tone sounds.
-
Using the SCV lever, close the gate. Verify that the display
changes back to 00 and the alarm tone goes off.
-
Press the PLUS key until the digital display shows CH015.
-
Release the keys and view the reading on the display. Verify
that the display reads 00.
-
Using the SCV lever, raise the gate to full height.
-
Verify that the display reads 012 and the alarm tone sounds.
|
Diagnostic Channel
|
Function
|
Display Reading
Switch Open (Gate Closed)
|
Display Reading
Switch Closed (Gate Open)
|
|
014
|
Right-Hand Gate Latch Proximity Switch
|
00
|
012 (Tone)
|
|
015
|
Left-Hand Gate Latch Proximity Switch
|
00
|
012 (Tone)
|
-
Using the SCV lever, close the gate. Verify that the display
changes back to 00 and the alarm tone goes off.
-
If readings are not as shown, adjust the switch position and
test again. (See ADJUST GATE LATCH PROXIMITY SWITCHES in Service-Baler
section.)
-
If the switch adjustment does not produce normal readings:
-
Turn the monitor-controller OFF. Turn the tractor key to the
OFF position and remove the key.
-
Check the wire harness for cuts and breaks.
-
Check harness connectors for damaged (pushed back) terminals.
-
Check for correct wire connections. (See WIRE HARNESS DIAGRAM—BALER
in Service—Baler section.)
-
Replace the switch if necessary. (See a John Deere dealer or
qualified service provider.)