Test Net Wrap Actuator Current (Channel 018)
Channel 018 allows operator use of EXTEND and RETRACT
keys to position net actuator for service.

E52520-UN-26JUN03
BaleTrak™ Pro Monitor-Controller

E84427-UN-06SEP17
BaleTrak Plus Monitor-Controller
A - COUNTER Key
B - EXTEND Key
C - RETRACT Key
This test is used to determine the working condition of the
actuator through its entire range of operation.
To test actuator (motor and linkage):
-
Turn tractor key to ON position. Do not start tractor engine.
-
With monitor-controller in NET mode, press and hold COUNTER
key (A) while turning monitor-controller ON.
-
Continue to hold COUNTER key and press PLUS key until CH 018 appears in digital display.
-
Release COUNTER key; digital display changes to show actuator
static current flow reading of 0—1.
-
To operate the actuator in both directions, use the EXTEND and
RETRACT (B and C) keys. Display must show a current flow reading between
1—8 while actuator motor is operating during mid stroke (no load).
-
Below normal readings indicate low tractor voltage, or poor
or corroded harness connections
-
Above normal readings indicate binding linkage or partially
shorted motor windings
-
Current spike reading indicates mechanical obstruction to linkage
-
Net wrap actuator is at full stroke position when actuator
is fully extended.
Continue to operate the actuator to full stroke position. Display
must show stall (load) current reading between
20—30.
-
Below a normal reading indicates bad or corroded harness connections
-
Above a normal reading indicates partially shorted motor windings
or actuator binding
-
To move the counterknife to the home position, press the EXTEND
or RETRACT (B and C) keys.
-
Turn monitor-controller OFF. Turn tractor key to OFF position.
Remove key.
|
|
SF04007,0000FBF-19-20170906
|
|