Testing Twine Wrap Actuator Current (Channel 018)

E52520-UN-26JUN03
A - COUNTER Key
B - EXTEND Key
C - RETRACT Key
Current overload protection to twine actuator is
bypassed when using channel 018. Extended use of channel 018 may cause
actuator damage.
Channel 018 allows operator use of EXTEND and RETRACT
keys to position twine actuator for service.
This test is used to determine the working condition of the
actuator through its entire range of operation.
To test actuator (motor and linkage):
-
Turn tractor key to ON position. Do not start tractor engine.
-
Press and hold COUNTER key (A) while turning monitor-controller
ON.
-
Continue to hold COUNTER key and press PLUS key until CH018 appears in digital display.
-
Current flow readings shown on digital display are relative
numbers, not indications of measurable units (amps).
Release COUNTER key; digital display will change to show actuator
static current flow reading of 0to 1.
-
Use EXTEND and RETRACT keys (B) and (C) to operate actuator
in both directions. Display should show a current flow reading between 1 and 8 while actuator
motor is operating during mid stroke (no load).
-
Below normal readings indicate low tractor voltage, or poor
or corroded harness connections
-
Above normal readings indicate binding linkage or partially
shorted motor windings
-
Current spike reading indicates mechanical obstruction to linkage
-
Continue to operate actuator to fully retracted position. Display
should show stall (load) current reading
between 22 and 30.
-
Below normal reading indicates bad or corroded harness connections
-
Above normal reading indicates partially shorted motor windings
or actuator binding
-
Press EXTEND or RETRACT keys to move actuator to "home" position.
-
Turn monitor-controller OFF. Turn tractor key to OFF position.
Remove key.
|
|
PP98408,00000D6-19-20090514
|
|