Testing Tractor Convenience Outlet Voltage (Channel 019)

E52521-UN-26JUN03
A - COUNTER Key
B - RETRACT Key
C - EXTEND Key
D - PLUS Key
Channel 019 allows operator use of EXTEND and RETRACT
keys to position actuator for service.
Complete the following check to determine if the convenience
outlet provides adequate power to the BALETRAK Pro system.
-
Start tractor engine.
-
Press and hold COUNTER key (A) while turning monitor-controller
ON.
-
Continue to hold COUNTER key and press PLUS key (D) until CH019 appears in the digital display.
-
Release COUNTER key and view voltage readout.
-
Using EXTEND key (C), extend twine actuator slightly.
-
Push and hold RETRACT key (B) until actuator stalls out in the
fully retracted position. Note voltage displayed during the first
four seconds after stalling.
| | |
|
Convenience Outlet | Voltage (Minimum) | 9.7 V |
-
If voltage is less than specifications, install Convenience
Outlet Kit AE50549. Only this kit should be used to provide a convenience
outlet, due to its wire size, lack of splices and circuit breaker
included in kit. When installing kit, attach power and ground wires
directly to battery terminal clamp bolts only. (See TRACTOR CONVENIENCE
OUTLET in Preparing the Tractor section.)
-
Turn monitor-controller OFF. Turn off tractor engine and remove
key.
|
BALE-TRAK is a trademark of Deere
& Company
|
PP98408,00000D7-19-20090514
|
|