Resetting BaleTrak™ Pro Monitor-Controller To Initial Settings (Channel 001)

E52442
E52442-UN-18JUN03

A - COUNTER Key

B - CH001 Displayed

All adjustable monitor-controller settings can be simultaneously reset to initial settings using the following procedure:

  1. Turn tractor key to ON position. Do not start tractor engine.

  2. Press and hold COUNTER key (A) while turning monitor ON.

  3. Release key; digital display should show 050.

  4. Simultaneously press and hold PLUS and MINUS keys until digital display changes from 050 to 099; then release keys.

    Display change is a visual indication that adjusted set points have reverted back to initial settings. (See BaleTrak™ Pro MONITOR-CONTROLLER SETUP VALUES AND INITIAL SETTINGS, in this section, to see which settings have changed.)

  5. Turn monitor off to enter initial settings into memory.

    • If in English units, the reset values will be in English.
    • If in metric units, the reset values will be in metric.

  6. Turn tractor key to OFF position. Remove key.

PP98408,0000207-19-20090910