BaleTrak™ Pro Monitor-Controller Setup Values and Initial Settings

BALE DIAMETER

Readout Display Range

77—160 cm (30.5—63 in)

Diameter Adjustment Range

91—152 cm (36—60 in)

Diameter Initial Setting1

142 cm (56 in)

Near Full-Size Range

1—27 cm (0.5—10.0 in)

Near Full-Size Initial Setting1

4.5 in (11 cm)

TWINE WRAP

Spacing Range

2—26 cm (1—10 in)

Spacing Initial Setting1

10 cm (4 in)

Number of End Wraps Range

Left-Hand End

0—5 Wraps

Right-hand End

0.5—5 Wraps

Number of End Wraps Initial Setting1

2 Wraps

Left-Hand End Wrap Distance Range

8—26 cm (3—10 in)

Right-Hand End Wrap Distance Range

8—26 cm (3—10 in)

End Wrap Distance Initial Setting (Right and Left-Hand)1

10 cm (4 in)

Re-Extension Wrap Distance

OFF1, 20, 40, 60 cm (8, 16, 24 in)

Cinch Wrap Setting (From Left-Hand End)

OFF1, 26 cm (10 in)

Dry Straw

OFF1, On

Delay of Twine Eject

0—10 Seconds

Delay of Twine Eject, Initial Setting

0 Seconds

1 Settings revert to these values when the monitor-controller is reset. (See Resetting BaleTrak™ Pro Monitor-Controller To Initial Settings [CH 001] in this section.)

SF04007,000108E-19-20171115