Adjusting Cleaning Fan Speed Actuator
1.
Adjust inner nuts (A) inward to end of threads next to gear. Adjust outer nuts (B) to outside end of shaft.
2.
Start engine. Engage separator. Adjust fan speed to 1400 rpm. Disengage separator.
3.
Stop engine and remove key.
4.
Adjust the two inner nuts against trunnion (C).
5.
Start engine, engage separator and adjust fan speed to 700 rpm. Disengage separator.
6.
Stop engine and remove key.
7.
Adjust the two outer nuts against trunnion.
|