CONTOURMASTER™ Angle Sensor Calibration

The CONTOURMASTER ™ angle sensor is calibrated using the CONTOURMASTER ™ calibration procedure. The CONTOURMASTER ™ calibration procedure must be performed before initial use or when the CONTOURMASTER ™ sensor is replaced.

Prepare the header for calibration:

Make sure the CONTOURMASTER ™ sensor is operating.

Start the combine and raise the header completely.

CONTOURMASTER is a trademark of Deere & Company.

AG,OUO1035,1380 -19-05JAN00-1/12


Press the diagnostic switch. DIA will appear on the triple display tachometer.

H54583

AG,OUO1035,1380 -19-05JAN00-2/12


Press the calibration switch. CAL and conc will appear on the tachometer.

H54595

AG,OUO1035,1380 -19-05JAN00-3/12


Press the up or down arrow switch to access the tiLt calibration mode. CAL and tiLt will appear on the tachometer.

H54610

AG,OUO1035,1380 -19-05JAN00-4/12


Press the enter switch. tiLt and L - dn will appear on the tachometer.

H54611

AG,OUO1035,1380 -19-05JAN00-5/12


To establish the left tilt sensor setting:

Press and hold the left side of the tilt switch (A) until the feeder house rotates completely to the left. This establishes the left tilt sensor setting.


A-Tilt Switch

H54612

AG,OUO1035,1380 -19-05JAN00-6/12


Press the calibration button. tiLt and r - dn will appear on the tachometer.

H54613

AG,OUO1035,1380 -19-05JAN00-7/12


To establish the right tilt sensor setting:

Press and hold the right side of the tilt switch (A) until the feeder house rotates completely to the right. This establishes the right tilt sensor setting.


A-Tilt Switch

H54614

AG,OUO1035,1380 -19-05JAN00-8/12


Press the calibration switch. tiLt and cntr will appear on the tachometer.

H54615

AG,OUO1035,1380 -19-05JAN00-9/12


Use the tilt switch (A) to level the feeder house.

For a visual indication of whether the header is level with the combine chassis, the CONTOURMASTER ™ feeder house is equipped with a manual indicator.

When the notch (B) is in the center of the rubber seal, the header is approximately level with the combine body.


A-Tilt Switch
B-Notch

H54616
H62284

CONTOURMASTER is a trademark of Deere & Company.

AG,OUO1035,1380 -19-05JAN00-10/12


Press the calibration switch. EOC will appear on the tachometer.

H54600

AG,OUO1035,1380 -19-05JAN00-11/12


Press the enter switch to store the calibration value or press the back arrow switch to abort the calibration (and not save values).

Press the back arrow switch to return to normal operation.

H54605

AG,OUO1035,1380 -19-05JAN00-12/12