Lack of Or Insufficient Cooling
|
Compressor belt broken or off.
|
Replace belt.
|
|
Compressor not functioning (if both the large and small hoses in the left hand access panel are at the same temperature).
|
See your John Deere dealer.
|
|
High pressure switch on - insufficient air flow across condenser.
|
Clean condenser. Check fan belt condition. Check engine fan speed belt position. Check rotary screen function.
See your John Deere dealer.
|
|
Low-pressure switch on - insufficient air flow across evaporator
|
Clean filters. Check cab fan operation.
See your John Deere dealer.
|
|
Low-pressure switch on - low outside air temperature.
|
Turn dial to warmer setting.
|
|
Low-pressure switch on - insufficient refrigerant level (bubbles in sight glass).
|
See your John Deere dealer.
|
|
Heater valve partially on - (with temperature dial turned to maximum [air conditioning], feel both heater hoses on right-hand side of cab. If both are warm, valve is open).
|
Adjust control rod through tray opening. Turn dial to OFF. Loosen set screw in ball joint and when applying slight pressure down on rod, tighten ball joint.
|
Compressor clutch cycles excessively or compressor stays off up to 15 minutes.
|
Evaporator icing.
|
Adjust controls correctly. See OPERATORS STATION. Open louvers. Clean filters. Move lever to warmer setting.
|
Bad smell (foul odor) in cab.
|
Plugged drain tube. Dirty filters. Dirty cab.
|
Blow condensate tube. Clean filters. Vacuum out cab.
Be certain weep valve in condensate drain tube is installed.
|
Diagnostic light blinking
|
Fault with A/C system.
|
See your John Deere dealer.
|