Air Conditioning

Symptom Problem Solution

Lack of Or Insufficient Cooling

Compressor belt broken or off.

Replace belt.

Compressor not functioning (if both the large and small hoses in the left hand access panel are at the same temperature).

See your John Deere dealer.

High pressure switch on - insufficient air flow across condenser.

Clean condenser. Check fan belt condition. Check engine fan speed belt position. Check rotary screen function.

See your John Deere dealer.

Low-pressure switch on - insufficient air flow across evaporator

Clean filters. Check cab fan operation.

See your John Deere dealer.

Low-pressure switch on - low outside air temperature.

Turn dial to warmer setting.

Low-pressure switch on - insufficient refrigerant level (bubbles in sight glass).

See your John Deere dealer.

Heater valve partially on - (with temperature dial turned to maximum [air conditioning], feel both heater hoses on right-hand side of cab. If both are warm, valve is open).

Adjust control rod through tray opening. Turn dial to OFF. Loosen set screw in ball joint and when applying slight pressure down on rod, tighten ball joint.

Compressor clutch cycles excessively or compressor stays off up to 15 minutes.

Evaporator icing.

Adjust controls correctly. See OPERATORS STATION. Open louvers. Clean filters. Move lever to warmer setting.

Bad smell (foul odor) in cab.

Plugged drain tube. Dirty filters. Dirty cab.

Blow condensate tube. Clean filters. Vacuum out cab.

Be certain weep valve in condensate drain tube is installed.

Diagnostic light blinking

Fault with A/C system.

See your John Deere dealer.

AG,OUO1035,1641 -19-24JAN00-1/1