Adjusting Header Drop Rate
NOTE:
Lower header to ground to relieve circuit pressure before adjusting header drop rate.
WITHOUT ACTIVE HEADER CONTROL
™
: Loosen nut (A) and turn screw for faster drop rate, turn screw in for slower drop rate.
WITH ACTIVE HEADER CONTROL
™
: Adjust drop rate as described, open accumulator two turns and adjust with knob (B) as needed.
Tighten nut after adjusting.
A-Nut
B-Knob
|
Equipped with ACTIVE HEADER CONTROL™[vv471,1]
|